Panel with covered fastening PWS-PIR-PL-60

The elevtion made of this type of slabs gives the impression of a smooth surface (no visible connectors), thanks to which they are often used not only in industrial facilities.


























































* 1050 mm - standard module, 1000 mm - non -standard module
** Approximate mass masses are given for the thickness of the external sheets. 0.50mm and internal 0.40mm and standard module.
Permissible panel lengths depending on the color of the cladding (minimum length - 2.5 MB).
18 m



12 m



























9 m


































During projecting it’s important to include difference in temperature of external and internal cladding of sandwich panels. Gradients of temperatues due to difference in external temperature T1 and internal temperature T2 are dependent on few factors:
Purpose of building (range of temperatures inside building T2)
localization of building – position due to sun
colour of external steel cladding (T1).
Depending on latitude, height above sea level and distance from sea on europe continent are use 4 different levels of winter temperature (T1 – external cladding):
0, -10oC,
0, -20oC, (for ex. Poland)
0, -30oC, (for ex. scandinavian countries)
Temperatures of external cladding of roof panel which is covered with snow layer is 0oC.
For calculation was assumed external temperature in winter of -20 oC.
Temperature of external cladding T1 has maximum value during summer and is depending of colour and grade of reflection of surface. Values T1, which are minmal for calculation bearing status (SGN) and are proper for calculations of limit status of use (SGU) are:
where RG – grade of reflextion in ratio of magnesium oxide = 100%
Recommended ways of transport for sandwich panels:
Sandwich panels should be storage maximum 2 packages one on another.
In below chart you can see what is maximal quantity of panels in one package.
| thickness of panels | PWS-PIR-PL |
|---|---|
| 60 mm | 18 pcs. |
| 80 mm | 14 pcs. |
| 100 mm | 11 pcs. |
| 120 mm | 9 pcs. |
ATTENTION !!!
All packages should be storage on flat surface with possibility to discharging water.
In case of panels with visible fix(PIR-ST), upper side of package is elevation side, which is very important.
ATTENTION!
The Białowieża Forest, hundreds of kilometers of challenging routes, and the unique atmosphere of a cycling adventure. Our company was well represented at the Ultra Duch Puszczy 2026. Blachy Pruszyński was a partner of the event, actively supporting one of the most recognizable ultra-cycling events in Poland.
Read moreOn May 29, 2026, the Lubuskie Branch of the Polish Roofers’ Association was officially launched at […]
Read moreŁukasz Byśkiniewicz and Łukasz Jastrzębski stood on the podium of the Polish Rally Championship for the second time in a row. The TVN TURBO RALLY TEAM crew took 2nd place in the 10th anniversary edition of the Nadwiślański Rally, confirming their strong form at the start of the season and remaining among the top contenders in the RSMP overall standings.