Browse the page as: Customer
MENU

Product description

blacha na rąbek nano

Roof panels with standing seam

The edge finish option with cut edges enabling assembly on the start strip.

The edges are cut on two sides of the panel. This allows you to twist the panel depending on the direction in which the assembly is carried out.

The PD510 Nano panel only occurs in an option with cut edges.

Choose a coating:
Więcej informacji o powłokach
Poliester połysk — PS25

Technical specification of the coating

Grubość powłoki
25 µm
Odporność na korozję
Wysoka ★★★☆
Odporność na UV
Dobra ★★☆☆
Możliwość obróbki
Dobra ★★☆☆
Gwarancja estetyczna
10 lat
Gwarancja techniczna
30 lat

Available colours

PMG 35

Technical specification of the coating

grubość powłoki
35 µm
odporność na korozję
Wysoka ★★★☆
odporność na UV
Dobra ★★☆☆
możliwość obróbki
Dobra ★★☆☆
gwarancja estetyczna
15 lat
gwarancja techniczna
35 lat

Available colours

PURMAX 40 um

Technical specification of the coating

grubość powłoki
40 µm
odporność na korozję
Wysoka ★★★★
odporność na UV
Wysoka ★★★☆
możliwość obróbki
Wysoka ★★★☆
gwarancja estetyczna
20 lat
gwarancja techniczna
40 lat

Available colours

PURLAK 50 um

Technical specification of the coating

grubość powłoki
50 µm
odporność na korozję
Wysoka ★★★★
odporność na UV
Wysoka ★★★☆
możliwość obróbki
Wysoka ★★★☆
gwarancja estetyczna
do 30 lat
gwarancja techniczna
50 lat

Available colours

PURMAT 50 um

Technical specification of the coating

grubość powłoki
50 µm
odporność na korozję
Wysoka ★★★★
odporność na UV
Wysoka ★★★★
możliwość obróbki
Wysoka ★★★☆

Available colours

Firma PRUSZYŃSKI gwarantuje każdorazowo realizację poszczególnego zamówienia w jednakowym kolorze (odcieniu). Z uwagi na skomplikowanie procesów powlekania możliwe jest jednak występowanie różnic w odcieniach pomiędzy poszczególnymi dostawami.

Odpowiedzialność za kolor w związku z tym ograniczona jest jedynie do jednej dostawy.

W związku z powyższym w przypadku domawiania blach do konkretnej partii bardzo prosimy o zaznaczenie na zamówieniu lub poinformowanie Handlowca, iż jest to kontynuacja zlecenia oraz dostarczenia próbki kolorystycznej.

Celem zapewnienia spójności kolorystycznej płyty warstwowych z innymi elementami takimi jak np. obróbki blacharskie należy zamawiać je u jednego dostawcy.

Inspirations

Technical specification

General information

Installation : roof panels for seams should be mounted at positive temperatures. Pruszyński sheets allow a different assembly method, consistent with roofing art.


Effective width
510 mm

Seam high
25 mm

Material
S 250 GD + Z 200 or 275
Max. recommended length of sheet
9 mb
Min. length of sheet
0,5 mb
Thickness
0,50 / 0,70 mm
Covering
polyester glossy, polyester matt, PURLAK, PURMAT
Accessories
Screws, nails, sealing tapes, flashings
Appliance
covering of roofs with minimal slope 8o (14%)
Panel PD510 Nano przekroj

Recommendations

Składowanie paneli

Paczki powinno się przechowywać w suchych i przewiewnych pomieszczeniach nie dopuszczając do kondensacji wilgoci pomiędzy arkuszami. Opakowania zbiorcze należy układać na klockach o wysokości około 20 cm nad ziemią. Jeżeli panele mają być składowane dłużej niż 3 tygodnie od daty produkcji należy je przejrzeć, a następnie przełożyć poszczególne arkusze przekładkami tak, aby umożliwić swobodną cyrkulację powietrza. Wszelkie informacje o sposobie oraz okresie przechowywania umieszczane są bezpośrednio na folii ochronnej i etykietach towarowych produktu oraz w naszych folderach, instrukcjach montażu i stronie internetowej.

Folia ochronna

W celu zabezpieczenia paneli dachowych przed uszkodzeniami mechanicznymi stosuje się folię ochronną. Należy usunąć ją bezpośrednio na etapie montażu, a podczas składowania chronić arkusze przed wilgocią i słońcem. Nieprzestrzeganie powyższych zasad może doprowadzić do trudności w usuwaniu folii z arkuszy oraz zabrudzeń po kleju.

Konserwacja połaci

Dachy z paneli na rąbek w zasadzie nie wymagają specjalnych zabiegów konserwacyjnych. Niemniej jednak bez względu na lokalizację budynku, aby zapobiec wszelkiemu ryzyku przedwczesnego zestarzenia się, jego okładziny ścienne i dachowe podlegać muszą regularnym przeglądom i konserwacjom przynajmniej raz w roku. Z powierzchni paneli należy usunąć liście, które gnijąc powodują odbarwienia powłoki organicznej blachy oraz osady i pyły przemysłowe (np. pochodzące z zakładów wapienniczych, cementowni, hut i kopalń, itd.), które wchodząc w reakcję z wodą powodują uszkodzenie powłoki lakierniczej blach. Ewentualne ubytki w powłoce należy oczyścić i zamalować specjalnymi farbami zaprawkowymi.

Uwagi końcowe

1. Do cięcia blach należy stosować elektryczne nożyce wibracyjne lub skokowe, niblery oraz nożyce ręczne. Zabrania się używania narzędzi powodujących przy cięciu uszkodzenie powłoki lakierowanej i cynkowej na skutek wydzielania się ciepła, tj. szlifierek kątowych.

2. Po dachu można chodzić jedynie w obuwiu o miękkich spodach, stawiać stopy w dołach fal w miejscu łat. Zanim zacznie się chodzić po pokryciu dachu należy przykręcić wszystkie wkręty.

3. Drobne uszkodzenia powłoki podczas montażu można zamalować farbą do zaprawek. Powierzchnia musi być oczyszczona z brudu i tłuszczu.

4. Stalowe wióry pozostałe po cięciu i wierceniu muszą być usunięte za pomocą miękkiej zmiotki, gdyż rdzewiejąc powodują uszkodzenia powierzchni blach.

5. Brud, który powstaje w czasie pracy montażystów oraz w okresie eksploatacji powinien być usunięty za pomocą normalnych środków myjących.

6. Niedopuszczalne jest stosowanie jakichkolwiek obróbek blacharskich (w tym czap kominowych, rzygaczy rynnowych i itp.) z blach miedzianych na dachach i elewacjach krytych blachami ocynkowanymi lub powlekanymi.

Do you have questions?

Is it possible to make copper machining at the steel roof?
When using copper, be careful because copper oxides are very aggressive and cause corrosion of other metals. Therefore, on buildings, it cannot be combined with other metal species (copper enters into contact and causes electrolytic corrosion of other metals).
Why is the metal roofing sheets recommended for the renovation of old roofs?
This is directly related to its low weight. In the case of old roofs, the trusses of the renovated houses are often somewhat damaged by time. Therefore, it is safer to use a metal roofing tile, which weight oscillates at 4.7 kg/m2, than almost ten times a heavier ceramic tile than it. However, it is always worth verifying the condition of the roof truss, with a specialist and make sure that it does not require renovation or replacement. In such cases, the safety of residents or building employees, as well as the assembly team, is always a priority. In most situations, however, the condition of the structure without major problems allows the use of roof tiles, while the use of ceramic tile would not be possible.
Can you use an angle grinder when cutting sheets?
Modern roofing exclude the use of angle grinders for cutting. The use of this method of cutting the material is associated with the loss of warranty.The angle grinder during operation and cutting produces very large amounts of heat, which in turn damages the edges of the sheet, as well as the coating covering it. In addition, the filings extracting during operation blend into the surface of the blades, additionally creating potential corrosion outbreaks.The right way of cutting sheet metal is to use automatic jumps (so -called Nilerler) or hand scissors. They use the mechanical force to cut the sheet, without exposing it to high temperature jumps. In addition, it is worth remembering that after cutting it is good to train cut places with dedicated protective varnish or special paint.
Does the roof require maintenance?
Yes, each roof requires periodic inspections to check if there have been any damage. Most of the products offered by Blachy Pruszyński have various types of specialized coatings available (covered by the warranty), increasing the life and durability of sheet metal. Maintenance consists mainly in removing the deposits and chimney dust, which left for a longer period of time can lead to sheet metal damage. Particular attention should be paid to places around chimneys that are sensitive due to more demanding operating conditions. If during the coverage inspection, local damage to the paint coating will be noticed, paint corrections should be made. In such a situation, the best solution is to use dedicated gloss paints tailored to a given coating. Such paints are in a stringent offer of Pruszyńska sheet and it is strongly recommended to use company products, recommended for a given coating.
How to register and how does the warranty work?
In order to register the warranty, download the warranty registration available in files for download / printing or directly: Warranty registration and send it completed to the following address: guarantee@pruszynski.euThe warranty begins to apply on the day of purchase of the goods. Registration of warranty is necessary to quickly identify the purchased batch of goods.
How can you complain the product, where is the information?
Complaints should be submitted in a warehouse in which the purchase was made. In the event that the wholesaler has been closed (does not run a business), the filled print of the complaint application should be sent directly to Pruszyński Sp. z o.o. to: pruszynski@pruszynski.eu

Printing of the complaint application is available in files for download / prints or directly here: Complaints
Trapezoidal sheets

Worth seeing

Trapezoidal sheets

See the offer

Others in this category

Panel-PD510-P-S Panel PD 510 P-S
Roof panels with standing seam
See product
Panel-PD510-T-S Panel PD510 T-S
Roof panels with standing seam
See product
Panel-PD510-F-S Panel PD510 F-S
Panel with standing seam
See product

See our offer of accessories

Choose the best accessories for your roof!

Wkręty samowiercące typu TORX TORX self-drilling screws (staples)
Fasteners for trapezoidal sheets, roof tiles, karo panels (short)
See product
Listwa podkalenicowa Under-ridge strip
Roof flashings - Ventilation flashing
See product

News

Sports sponsorship
Volleyball Festival in Krakow - already 25-26.02.2023

The Pruszyński Group has been supporting Polish volleyball for over 15 years and it is undoubtedly […]

Read more
Business, Company events, What's new
The FincoStal brand disappears from the market - there is a full connection with Pruszyński sheet

Please be advised that on 01/03/2023 the Fincostal brand will be fully connected to Pruszyński sheet. Considering the interests of our contractors and clients, we took steps for this process to take place maximally smoothly, without any impact on the continuity of the offer and conditions.

Read more
Fairs, Courses, What's new
Budma 2023 - in a moment the start of the largest construction fair. We invite you to our stand.

The beginning of the year is full of unique industry meetings. After Dachforum 2023, which turned out to be a huge success, time for Budma, i.e. the largest event of the construction industry.

Read more