Pas nadrynnowy: TYP3

Over-gutter flashing with hem (2 ventilation rows)

The OVER-GUTTER flashing belongs to the eave flashings, placed along the lower edge of the roof (eave). It is made of galvanized sheet, 0.5mm thick, covered with a protective coating. Designed for standing seam panels, with additional perforation for improved ventilation.

Product description

schemat domu, dachy, obrobki blacharskie

EAVE flashings

Eaves flashings are one of the most important technical details of a roof, responsible not only for the aesthetic finishing of the slope edges, but above all for the proper functioning of the entire roofing system.

The most important tasks of eaves flashings include:

  • effective drainage of rainwater and meltwater into the gutter system,
  • protecting the roof layers against capillary rising,
  • protection of the eaves structure, fascia board, and facade against moisture,
  • ensuring the tightness of the roofing in the eaves area,
  • protecting the slope against wind-blown rain, snow, and strong winds,
  • ensuring proper ventilation of the roof slope,
  • drainage of condensate and moisture from the initial covering layer,
  • increasing the durability and operational safety of the roof.

Particular attention should be paid to the correct connection of eaves flashings with the roof membrane, gutter system, and ventilation elements. An incorrectly executed eaves detail can lead to moisture in the thermal insulation, degradation of the wooden structure, and limited effectiveness of the roof slope ventilation.

Over-gutter flashing with hem (2 ventilation rows)

The OVER-GUTTER flashing, often also referred to as a DRIP EDGE, is a roofing element responsible for draining water from the roof slope into the gutter. Its main role is to ensure the flowing water detaches from the slope and is redirected into the gutter. An additional element in the form of a so-called “hem” enables easy installation of standing seam panels and single-module roof tiles. Furthermore, special two-row ventilation improves air circulation under the roofing. Our offer includes 3 OVER-GUTTER flashings with a hem:

Choose a coating:
Protective coating
PURMATpolyurethane, matt

Technical specification of the coating

Thickness of coating
50 µm
Corrosion resistance
High ★★★★
UV resistance
High★★★★
Possibility of bending
High ★★★☆
Aesthetic guarantee
30 years
Technical guarantee
50 years

Available colours

PUM R011
PUM R011
PUM R028
PUM R028
PUM RR 033
PUM R033
PUM RR 750
PUM R750
PUM RAL 7016
PUM RAL 7016
PUM RAL 8017
PUM RAL 8017
PURLAKpolyurethane, glossy

Technical specification of the coating

Thickness of coating
50 µm
Corrosion resistance
High★★★★
UV resistance
High ★★★☆
Possibility of bending
High ★★★☆
Aesthetic guarantee
30 years
Technical guarantee
50 years

Available colours

PU RAL 7016
PU RAL 7016
PU RAL 9005
PU RAL 9005
TOPMATpoliyester, matt (Arcelor PL)

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High★★★☆
Aesthetic guarantee
20 years
Technical guarantee
35 years

Available colours

TOPMAT RR 033
TOPMAT R033
TOPMAT R750
TOPMAT R750
TOPMAT RAL 7016
TOPMAT RAL 7016
TOPMAT RAL 8017
TOPMAT RAL 8017
ULTRAMAT®poliyester, matt (Arcelor DE)

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High ★★★☆
Technical guarantee
20 years

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PMG35®poliyester, matt

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
Possibility of bending
Good ★★☆☆
Aesthetic guarantee
15 years
Technical guarantee
35 years

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PS25poliyester, glossy

Technical specification of the coating

Thickness of coating
25 µm
Corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
Possibility of bending
Good ★★☆☆
Aesthetic guarantee
10 years
Technical guarantee
30 years

Available colours

R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 7035
RAL 7035
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9002
RAL 9002
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
Metallic coatings

Technical specification of the coating

Available colours

powłoka AZ - aluzynk
AZ – aluzinc
Powłoka - OC - ocynk
OC – galvanized
Pruszyński Company guarantess realization of each order in one colour shade. Although due to technological process of covering paint to steel shets there is possibility for occuring difference in colour shade in different deliveries.

Regarding this please inform sales person if different delivery is continuation of previous orders.

Inspirations

Technical specification

General information

Length:
2 m
Thickness:
0,50
Coating
polyester glossy / polyester mat / polyurethane / zink / aluzinc
Pas nadrynnowy TYP3 - przekroj

Download

Production profile 2025
[PDF]
Wersja pliku: 25.3

Do you have questions?

Is it possible to make copper machining at the steel roof?
When using copper, be careful because copper oxides are very aggressive and cause corrosion of other metals. Therefore, on buildings, it cannot be combined with other metal species (copper enters into contact and causes electrolytic corrosion of other metals).
Why is the metal roofing sheets recommended for the renovation of old roofs?
This is directly related to its low weight. In the case of old roofs, the trusses of the renovated houses are often somewhat damaged by time. Therefore, it is safer to use a metal roofing tile, which weight oscillates at 4.7 kg/m2, than almost ten times a heavier ceramic tile than it. However, it is always worth verifying the condition of the roof truss, with a specialist and make sure that it does not require renovation or replacement. In such cases, the safety of residents or building employees, as well as the assembly team, is always a priority. In most situations, however, the condition of the structure without major problems allows the use of roof tiles, while the use of ceramic tile would not be possible.
Can you use an angle grinder when cutting sheets?
Modern roofing exclude the use of angle grinders for cutting. The use of this method of cutting the material is associated with the loss of warranty.The angle grinder during operation and cutting produces very large amounts of heat, which in turn damages the edges of the sheet, as well as the coating covering it. In addition, the filings extracting during operation blend into the surface of the blades, additionally creating potential corrosion outbreaks.The right way of cutting sheet metal is to use automatic jumps (so -called Nilerler) or hand scissors. They use the mechanical force to cut the sheet, without exposing it to high temperature jumps. In addition, it is worth remembering that after cutting it is good to train cut places with dedicated protective varnish or special paint.
Does the roof require maintenance?
Yes, each roof requires periodic inspections to check if there have been any damage. Most of the products offered by Blachy Pruszyński have various types of specialized coatings available (covered by the warranty), increasing the life and durability of sheet metal. Maintenance consists mainly in removing the deposits and chimney dust, which left for a longer period of time can lead to sheet metal damage. Particular attention should be paid to places around chimneys that are sensitive due to more demanding operating conditions. If during the coverage inspection, local damage to the paint coating will be noticed, paint corrections should be made. In such a situation, the best solution is to use dedicated gloss paints tailored to a given coating. Such paints are in a stringent offer of Pruszyńska sheet and it is strongly recommended to use company products, recommended for a given coating.
How to register and how does the warranty work?
In order to register the warranty, download the warranty registration available in files for download / printing or directly: Warranty registration and send it completed to the following address: guarantee@pruszynski.euThe warranty begins to apply on the day of purchase of the goods. Registration of warranty is necessary to quickly identify the purchased batch of goods.
How can you complain the product, where is the information?
Complaints should be submitted in a warehouse in which the purchase was made. In the event that the wholesaler has been closed (does not run a business), the filled print of the complaint application should be sent directly to Pruszyński Sp. z o.o. to: pruszynski@pruszynski.eu

Printing of the complaint application is available in files for download / prints or directly here: Complaints
Trapezoidal sheets

Worth seeing

Trapezoidal sheets

See the offer

See our offer of related products

Blachodachowka RUBIN Rubin
Custom -made metal roof tile
See product
Blachodachowka OPTIMA Optima
Custom -made metal roof tile
See product
Regle - Blachodachówka modułowa - panelowa Regle
Modular roof tile - panel
See product
Niagara kwadratowa - rynna Gutter
NIAGARA Square - gutters
See product
Taśma kalenicowa Ridge tape
Roof accessories
See product

News

Sports sponsorship
Volleyball Festival in Krakow - already 25-26.02.2023

The Pruszyński Group has been supporting Polish volleyball for over 15 years and it is undoubtedly […]

Read more
Business, Company events, What's new
The FincoStal brand disappears from the market - there is a full connection with Pruszyński sheet

Please be advised that on 01/03/2023 the Fincostal brand will be fully connected to Pruszyński sheet. Considering the interests of our contractors and clients, we took steps for this process to take place maximally smoothly, without any impact on the continuity of the offer and conditions.

Read more
Company events, Courses
Annual winter roofing training in Pruszyński sheet

Winter roofing training returned to the calendar again. The best roofers from all over Poland meet in Sokołów, gain knowledge, exchange techniques and discuss the development of the industry.

Read more