Browse the page as: Customer
MENU
PWS2-MW-ST-220 - Płyta warstwowa ścienna - wełna mineralna - widoczne mocowanie

PWS2-MW-ST-220 - Wall sandwich panel - mineral wool - visible fastening

A sandwich panel with coated steel cladding and a second-generation mineral wool core. Core thickness: 220 mm; visible interlocking joint.

Product Description

PIRTECH PLUS - PWS-PIR-PL-80 - plyta z ukrytym mocowaniem

Wall sandwich panels are used primarily in the construction of industrial and public-use buildings (shopping centers, warehouses, sports arenas, etc.). In addition to curtain walls, these panels are used as partition walls and as load-bearing walls in small mobile cold storage units, construction site facilities, and utility buildings.

A wide range of colors and a variety of panel profiles make it possible to create a number of interesting projects. The panels can be installed both vertically and horizontally.

Components

PWS2-MW construction product: crafted from superior materials on Europe’s most advanced production line dedicated to this product range

WOOLTECH Standard, plyta warstwowa rdzen welniany

Core

Mineral wool STANDARD

Structural-insulating core, made of the highest quality mineral wool with a density of 115 kg/m³ +/-10%. Mineral wool provides very good insulation parameters, but above all, fire and acoustic insulation. Bonded to the cladding with a two-component polyurethane adhesive.

Cladding

External steel cladding

Profile sheet, 0.5 – 0.7 mm thick, galvanized steel. Available profiling: trapezoidal (T), micro-trapezoidal (M), wave (W), nano-wave (N), and flat (F)*. Protected with lacquer and hybrid coatings.

only for sheets with thickness ≥ 0.6 mm

Cladding

Internal steel cladding

High-quality galvanized steel, 0.40 mm – 0.50 mm thick. Standard profiling – Trapezoidal (T) profiling available, with the option of an additional lacquer coating in a color from the available palette.

Fastening

Fastening

A new type of longitudinal fastening, tongue-and-groove type. High precision fit, ease of installation. Excellent insulation parameters and reduction of thermal bridges. NOTE – compatibility with PIRTECH type panels – allows for seamless joining of MW2 and PIRTECH panels.

Choose a coating:
More information about coatings
PURMATpolyurethane coating, matte

Technical specification of the coating

coating thickness
50 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★★
machinability
High ★★★☆

Available colours

PUM R011
PUM R011
PUM R028
PUM R028
PUM RR 033
PUM R033
PUM RR 750
PUM R750
PUM RAL 7016
PUM RAL 7016
PUM RAL 8017
PUM RAL 8017
PURLAKpolyurethane coating, gloss

Technical specification of the coating

coating thickness
50 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★☆
machinability
High ★★★☆

Available colours

PU RAL 7016
PU RAL 7016
PU RAL 9005
PU RAL 9005
PMG35®coarse-grained matte polyester

Technical specification of the coating

coating thickness
35 µm
corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
machinability
Good ★★☆☆

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PS25glossy polyester

Technical specification of the coating

Coating thickness
25 µm
Corrosion Resistance
High ★★★☆
UV resistance
Good ★★☆☆
Machinability
Good ★★☆☆

Available colours

R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3011
RAL 3011
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7035
RAL 7035
RAL 9002
RAL 9002
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7035
RAL 7035
RAL 9002
RAL 9002
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
RAL 1002
RAL 1002
RAL 3011
RAL 3011
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6029
RAL 6029
RAL 7035
RAL 7035
RAL 9002
RAL 9002
RAL 7016
RAL 7016
RAL 8017
RAL 8017
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
The Pruszyński Company guarantees that each order will be produced in the same color (shade). However, due to the complexity of the coating processes, slight variations in shades may occur between individual shipments; therefore, our responsibility for color consistency is limited to a single shipment. When reordering sheets from a specific batch, please indicate on the order form or inform your sales representative that this is a continuation of a previous order and provide a color sample. To ensure color consistency between sandwich panels and other components, such as flashings, please order them from a single supplier.

Inspiration

Multi-storySingle-family home

Single-family home in Ostrava

PD-510 Standing Seam Roof Panels

Commercial Investments

University Sports Center in Rzeszów

University Sports Center in Rzeszów

Single-family home

Single-family home in Stąporków

MODUS Metal Roof Tile

Commercial Investments

Orientarium, Łódź Zoo

The Breeding and Exhibition Orientarium Building at the Łódź Zoo

Single-family home

A single-family home in the village of Tumlin

MODUS Metal Roof Tile

Multi-storySingle-family home

Single-family home in the village of Przeczów

OPTIMA Metal Roof Tile

Commercial Investments

Car dealership in Mikołów

BMW M Dealership in Mikołów

One-storySingle-family home

A single-family home and a garden shed in Wola Rzędzińska

SZAFIR Metal Roof Tile

One-storySingle-family home

Single-family home in Wola Rzędzińska

REN Metal Roof Tile

One-storySingle-family home

Single-family home in Rytwiany

MODUS Metal Roof Tile

Multi-storySingle-family home

Two-story single-family home in Józefów

STAND-UP SEAM ROOF PANELS

Single-family home

Single-family home in Białystok

REGLE Roof Panels

One-storySingle-family home

Single-family home in Bydgoszcz

STAND-UP SEAM ROOF PANELS

Commercial Investments

Polonez Plus in Kielce

The Polonez Plus manufacturing plant in Kielce

One-storySingle-family home

Single-family home in Końskie

REN metal roof tiles combine durability and aesthetics

Commercial Investments

Pex-Pool Plus Dębica

Pex-Pool Plus Dębica

Commercial Investments

"Dwór Dobarz" Guesthouse

REGLE roof panels, imitation wood shingles, Zakopane style

One-storySingle-family home

Single-family home in Stąporków

The PŁASKA PLUS metal roof tile is an excellent choice for modern construction, and its flat surface is very popular among developers.

One-storySingle-family home

Single-family home in Wola Rzędzińska

TIGRA Metal Roof Tiles — the perfect solution for homeowners looking for a flat roof surface

One-storySingle-family home

Single-family home in Wymysłowo

The RUBIN metal roof tile is a harmonious blend of classic style and functionality.

One-storySingle-family home

Single-family home in Białystok

A classic with a modern twist. FIORD metal roof tiles used to cover a single-story house with a modern design.

Single-family home

Single -family House Tuczępa

Single-family home

A single -family house in Rytwiny

Single-family home

Single -family house, Staszów

Single-family home

Villa Niepołomice

Single-family home

Arkadia Investment housing estate

Commercial Investments

Sevilla Gold Hotel

Single-family home

Single-family home, Pliskowola

Commercial Investments

Arena Grupa Azoty in Puławy

Commercial Investments

Kielce Bus Station

Avant-garde design in a public building

Single-family home

A single -family house in Rudna near Rzeszów

Flat metal sheet, single -family house in Rudna

Single-family home

Gable-roofed house in Końskie

Commercial Investments

Flat metal tile market, Orzysz

Single-family home

Trapeze

Single-family home

Modus

Single-family home

Detached house complex roof. Modus roof tile

Modus metal roof tile, multi -track roof

Commercial Investments

Mercedes

Mercedes

Commercial Investments

Leroy Merlin

Leroy Merlin

Technical specification

Technical Information

The PWS2-MW sandwich panel is a new, improved generation of our highly rated product—the Sandwich panel with a Mineral Wool core. For products intended for wall assembly, our product line includes two variants: a panel with a visible lock and a panel with a hidden joint.
Key product features: a 220-mm-thick, wall sandwich panel with a Mineral Wool core and exposed interlocking joints, with a density of approximately 115kg/m³

* External flat profiling (P), available only for sheet thicknesses greater than 0.6 mm
** Weight specified for *cladding with a thickness of 0.5 mm / 0.5 mm

core
Mineral wool
panel thickness
220 mm
effective width
1150 / 1100 / 1000 mm
overall width
1170 / 1120 / 1020 mm
weightper 1 m²
33.15 kg **
min. panel length
2.0 mb
Maximum panel length
see - panel lengths
sheet metal thickness
0.5–0.7 mm (outer)
type of external profiling
trapezoid - T
micro-trapezoid - MT
wave – F
nano-wave - N
flat - P*
type of internal profiling
trapezoid - T
flat - P
coatings
glossy/matte polyester, polyurethane, HPS200
plyta warstwowa II welna 220

Physical Properties

You will find the product’s basic technical and physical specifications in the tables and lists below. For more detailed information about the benefits of our products, please contact us directly at the following email address: inwestycje@pruszynski.euRegarding approvals and certificates—complete documentation can be found in the DOWNLOADS section

Thermal Parameters
Declared thermal conductivity coefficient of the core – [W/mK]
0,041
Heat transfer coefficientUc – [W/m²K]
0,18
Heat transfer coefficientUds – [W/m²K]
0,18
fire spread rating / fire reaction
NRO / A2-s1, d0
Fire resistance
as an exterior/interior wall

EI120 (o↔i)
(horizontal 7.5 m, vertical 7.5 m)

EI180 (o↔i)
(horizontal 4.0 m, vertical 6.0 m)

EI240 (o↔i)
(horizontal 4.0 m)
Acoustic Parameters
sound insulation (dB)
Rw: 30 dB
RA1: 27 dB
RA2: 26 dB
sound absorption (αw)
NPD

Panel lengths

The table below shows the classification by color group for the individual colors available in the Pruszyński Company product line. Permissible panel lengths depending on the cladding color (minimum length—2.5 running meters) for single-span installations. The assembly of panels that exceed the recommended lengths is the responsibility of the customer.

Group I (very light colors)

Maximum length

16 m wall / 16 m roof

RAL 9002
RAL 9002
RAL 9010
RAL 9010
<span style="color:#e20a17">RAL 9001*</span>
RAL 9001*

Group II (light colors)

Maximum length

12 m wall / 12 m roof

RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 7000
RAL 7000
RAL 7035
RAL 7035
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
<span style="color:#e20a17">RAL 1003*</span>
RAL 1003*
<span style="color:#e20a17">RAL 1004*</span>
RAL 1004*
<span style="color:#e20a17">RAL 1014* </span>
RAL 1014*
<span style="color:#e20a17">RAL 1017* </span>
RAL 1017*
<span style="color:#e20a17">RAL 1019*</span>
RAL 1019*
<span style="color:#e20a17">RAL 1023*</span>
RAL 1023*
<span style="color:#e20a17">RAL 1035*</span>
RAL 1035*
<span style="color:#e20a17">RAL 2000*</span>
RAL 2000*
<span style="color:#e20a17">RAL 2003*</span>
RAL 2003*
<span style="color:#e20a17">RAL 2004*</span>
RAL 2004*
<span style="color:#e20a17">RAL 2008*</span>
RAL 2008*
<span style="color:#e20a17">RAL 2009*</span>
RAL 2009*
<span style="color:#e20a17">RAL 5012*</span>
RAL 5012*
<span style="color:#e20a17">RAL 5018*</span>
RAL 5018*
<span style="color:#e20a17">RAL 5024*</span>
RAL 5024*
<span style="color:#e20a17">RAL 6018*</span>
RAL 6018*
<span style="color:#e20a17">RAL 6021*</span>
RAL 6021*
<span style="color:#e20a17">RAL 6033*</span>
RAL 6033*
<span style="color:#e20a17">RAL 7037*</span>
RAL 7037*
<span style="color:#e20a17">RAL 7040*</span>
RAL 7040*
<span style="color:#e20a17">RAL 9022*</span>
RAL 9022*

Group III (dark colors)

Maximum length

9 m wall / 9 m roof

RAL 3005
RAL 3005
RAL 3011
RAL 3011
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 8017
RAL 8017
RAL 8023<br><span style="font-size: 7pt;">COPPER</span>
RAL 8023
COPPER
RAL 9005
RAL 9005
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
PMG R750
PMG R750
PMG R011
PMG R011
PMG R028
PMG R028
PMG R033
PMG R033
Dark Walnut
Dark Walnut
Golden Oak
Golden Oak
PUM R028
PUM R028
<span style="color:#e20a17">RAL 3000*</span>
RAL 3000*
<span style="color:#e20a17">RAL 3002*</span>
RAL 3002*
<span style="color:#e20a17">RAL 3003*</span>
RAL 3003*
<span style="color:#e20a17">RAL 3013*</span>
RAL 3013*
<span style="color:#e20a17">RAL 5002*</span>
RAL 5002*
<span style="color:#e20a17">RAL 5005*</span>
RAL 5005*
<span style="color:#e20a17">RAL 5009*</span>
RAL 5009*
<span style="color:#e20a17">RAL 5011*</span>
RAL 5011*
<span style="color:#e20a17">RAL 5022*</span>
RAL 5022*
<span style="color:#e20a17">RAL 6000*</span>
RAL 6000*
<span style="color:#e20a17">RAL 6003*</span>
RAL 6003*
<span style="color:#e20a17">RAL 6011*</span>
RAL 6011*
<span style="color:#e20a17">RAL 6020*</span>
RAL 6020*
<span style="color:#e20a17">RAL 7015*</span>
RAL 7015*
<span style="color:#e20a17">RAL 7022*</span>
RAL 7022*
<span style="color:#e20a17">RAL 8016*</span>
RAL 8016*
ATTENTION! Given that dark-colored panels from Group III are subject to significantly higher thermal loads than very light- and light-colored panels from Groups I and II, it is necessary to assess during the design phase, depending on the loads, which panel layout on the wall is feasible.
* Colors marked with an asterisk are not available in the standard product range. Please submit individual inquiries regarding colors directly via the contact form.
Read more below.

Recommendations for Selecting Plates in the Context of Thermal Loads

NOTE – Group III – dark colors

Given that dark colors in Group III are subject to significantly higher thermal loads than very light and light colors in Groups I and II, special care must be taken during the design process to ensure that the following conditions are met:

  • The fastening method and static configuration must comply with the permissible load tables and spans (criteria met—ultimate limit state, serviceability limit state)*
  • Limit the maximum length of the panels according to the manufacturer’s recommendations**
  • Take the assembly temperature into account***

* For dark-colored panels, single-span configurations are recommended; otherwise, deformations in the panel’s exterior cladding may occur at intermediate supports, which are not acceptable to the Investor. The corrugations in question meet the requirements of the PN EN 14509 standard in terms of permissible deviations; however, they may be grounds for a complaint.

** The maximum panel lengths should comply with the manufacturer’s guidelines, depending on the type of panel and its application (roof/wall)—see PANEL LENGTHS.

*** Assembly of dark-colored panels can be performed at temperatures ranging from10°Cto35°C. This condition must be strictly observed. Assembly at temperatures below10°C(or above35°C) may lead to deformation and permanent damage to the panel during the building’s service life (and, in extreme cases, even during assembly). In this case, panel deformation and damage are caused by the high elongation of the cladding (e.g., at summer temperatures) relative to its initial length (the length of the cladding at the time of assembly).

Assembly of light- and very light-colored panels can be performed at temperatures ranging from+5°Cto+35°C.

Failure to follow the above guidelines may result in surface deformation of the panels and localized loss of stability, for which the manufacturer assumes no liability. For colors not listed in the table, please contact a Pruszyński Company technical advisor. The color of the panel may be changed only with the designer’s approval.

Shipping Recommendations

Recommended modes of transportation for sandwich panels:

  • a truck (tractor unit + semi-trailer with a length no shorter than the length of the loaded panels) with an open semi-trailer or one that allows for side loading on both sides along its entire length
  • The load weight must not exceed the permissible load capacity of the vehicle combination,
  • Transport straps should be placed on the load at intervals of no more than 3 m, but no fewer than 2 straps per package—the tension of the straps must not cause the slabs to deform.

Storage Recommendations

Sandwich panels should be stored in stacks; a maximum of two stacks may be stacked on top of each other
The table below lists the maximum number of panels that can be stacked in a single stack.

panel thicknessPWS2-MW-ST
60 mm18 pcs.
80 mm14 pcs.
100 mm11 pcs.
120 mm9 pcs.
140 mm8 pcs.
160 mm7 pcs.
180 mm6 pcs.
200 mm5 pcs.
220 mm5 pcs.
240 mm4 pcs.
260 mm4 pcs.

 

  • It is recommended to store the panels on a level surface (yard, warehouse) on joists or polystyrene pads, which must be spaced no more than 2.5 m apart (for panels with a total length of up to 2.5 m, use at least 3 blocks).
  • A maximum of two stacks of boards up to 6 meters in height may be stacked on top of each other; stacks of boards exceeding 1 meter in height must be stored individually. All stacks of boards must be stored on a level surface with proper drainage.
  • When storing panels on a construction site, they must be protected against mechanical damage, UV exposure, harsh environmental conditions (acids, fertilizers, salts, and other corrosive agents), precipitation, strong winds, and other factors.
  • It is recommended to store packages under a roof in well-ventilated areas
  • The panels should be stored on a level surface (yard, warehouse) on joists, on polystyrene or wooden supports, which must be spaced no more than 2.5 m apart (for panels with a total length of up to 2.5 m, use at least 3 supports).
  • Protective films are used to provide additional protection for the surfaces of the panels against mechanical damage, stress, and impacts that may occur during transport or handling. These films do not exempt users from the obligation to properly secure the panels during storage.
  • It is recommended to remove the protective film before installing the components on the building’s facade or roof. The film should be removed when the air temperature is above freezing, because at sub-freezing temperatures the adhesive delaminates and some of its components may remain on the sheet metal.
  • Improper storage of the sheets may make it difficult to remove the protective film and may leave adhesive residue on the surface of the sheets. In such cases, the Manufacturer will not honor claims regarding adhesive residue left by the protective film.
  • For panels with hidden fasteners, be sure to remove the film from the inside of the longer lock before assembly.

ATTENTION!!!

For wall panels with visible fastening, the top side of the panels in the package is the facade side; please pay special attention to this!

Maintenance and Cleaning

To extend the service life of roofs and facades made of coated sheet metal, they should be inspected and maintained regularly.

  • Inspection – Once a year (preferably in the spring), you should inspect the roof and exterior walls to detect any damage early on.
  • Cleaning Sheet Metal – Roofs and facades made of coated sheet metal require cleaning at least once a year. Dirt that accumulates on the sheet metal can cause uneven discoloration (due to uneven exposure to UV rays) and reduce corrosion resistance (dirt traps moisture on the sheet metal, gradually damaging it). Dirty and stained areas can be cleaned with a soft brush and water (max. 60°C). If necessary, a mild detergent (pH 6–7, max. 10% solution) may be added to the water. Pressurized water (max. 100 bar) may also be used for cleaning; however, the water jet must not be directed too close to the panel surface (min. 30 cm) nor perpendicular to the surface. At the joints, the water jet should be directed downward to prevent pressurized water from penetrating the gaps around the joints. Old panel coatings must be handled with extreme care. Cleaning should be performed from top to bottom, and the cleaned area should always be thoroughly rinsed with clean water immediately.
  • Do not use scouring powders, nitro solvents, chlorine-based solutions, aromatic cleaners, or products containing ammonium chloride or sodium salts.
  • Damage — Any damage that occurs during the Warranty period must be discussed with the roofing/facade contractor and may be repaired only with the contractor’s written consent. Repairs to small areas are carried out using air-drying touch-up paints, while painting large areas is generally only possible using special industrial paints designed for the renovation of coatings. The surface to be painted should be limited only to areas that require it (scratches down to the metal, corrosion spots, etc.). Surface preparation for painting should be performed in accordance with generally accepted guidelines. Always thoroughly remove all traces of corrosion—preferably using special brushes or fine-grit sandpaper. Next, the surface to be repaired must be thoroughly dusted, degreased, and cleaned. To degrease the surface, you can use extraction gasoline or water with added surfactants (preferably with a 1–2% ammonia solution). The repaired areas may show color differences compared to the original sheet metal colors due to natural atmospheric effects (aging of the paint under the influence of UV radiation).
  • Organically coated steel sheets must not be used in:
    • an environment in constant contact with highly saline water,
    • contact with construction chemicals, including concrete, plaster, wet wood, etc.,
    • in an environment exposed to harsh chemicals
    • in combination with materials having a different electrochemical potential
  • CAUTION—Health and safety rules must be strictly observed during inspection, cleaning, maintenance, and repairs.

The Pruszyński Company is not liable for any accidents that may result from performing the above activities.

Do you have any questions?

Does the roof need maintenance?
Yes, every roof requires periodic inspections to check for any damage. Most products offered by the Blachy Pruszyński Company are available with various types of specialized coatings (covered by Warranty) that increase the service life and durability of metal roofing. Maintenance mainly involves removing soot and chimney dust, which, if left for an extended period, can damage the metal sheeting. Particular attention should be paid to the areas around chimneys, which are critical due to more demanding operating conditions. If localized damage to the paint coating is noticed during an inspection of the roofing, touch-up painting should be performed. In such situations, the best solution is to use dedicated touch-up paints matched to the specific coating. The Blachy Pruszyński Company offers such paints as part of its regular product line, and it is strongly recommended to use the company’s products that are recommended for the specific coating.
Is it possible to install copper flashings on a steel roof?
Caution must be exercised when using copper, as copper oxides are highly corrosive and cause corrosion of other metals. For this reason, it must not be combined with other types of metals on buildings (copper reacts upon contact and causes electrolytic corrosion of other metals).
Can I use an angle grinder to cut sheets?
Modern roof coverings preclude the use of angle grinders for cutting. Using this method to cut the material will void the Warranty.
An angle grinder generates a great deal of heat during operation and cutting, which in turn damages the edges of the sheet metal as well as its protective coating. Additionally, the metal shavings produced during operation become embedded in the sheet metal’s surface, creating potential corrosion sites.
The proper way to cut sheet metal is to use automatic nibblers or hand shears. These tools use mechanical force to cut the sheet metal without exposing it to extreme temperature fluctuations. Additionally, it’s worth remembering that after cutting, it’s a good idea to protect the cut edges with a dedicated protective varnish or special paint.
Why are metal roof tiles recommended for renovating old roofs?
This is directly related to its light weight. In the case of old roofs, the roof trusses of renovated houses are often already somewhat worn down by time. Therefore, it is safer to use metal roof tiles, which weigh around 4.7 kg/m², rather than ceramic roof tiles, which are nearly ten times heavier. However, it’s always a good idea to have a specialist inspect the condition of the roof truss and confirm whether it requires renovation or replacement after all. In such cases, the safety of the building’s residents or employees, as well as the installation crew, is always the top priority. In most situations, however, the condition of the structure allows for the use of metal roof tiles without major issues, whereas the use of ceramic roof tiles would no longer be possible.
How can I advertise a product? Where can I find more information?
Complaints should be filed at the wholesale store where the purchase was made. If the wholesale store in question has closed (is no longer in business), the completed complaint form should be sent directly to Pruszyński Company at the following address: pruszynski@pruszynski.com.pl

A complaint form is available in the "Downloads / Forms" section or directly here: COMPLAINT FORM
How to register and how does the warranty work?
In order to register the warranty, download the warranty registration available in files for download / printing or directly:
Warranty registration and send it completed to the following address: guarantee@pruszynski.eu

The warranty begins to apply on the day of purchase of the goods. Registration of warranty is necessary to quickly identify the purchased batch of goods.

Other items in this category

NIAGARA Metal Round NIAGARA Metal Round
Metal round gutters with a protective coating
See product
NIAGARA Round (polyurethane) NIAGARA Round (polyurethane)
NIAGARA Round - polyurethane
See product
Gutter Gutter
NIAGARA Round gutters
See product
NIAGARA Stalowe - zlaczka rynny Gutter connector
NIAGARA Round gutters
See product
Denko rynny PLUS sqare Gutter End PLUS
NIAGARA Round gutters
See product
Denko rynny głebokie sqare Deep gutter end
NIAGARA Round gutters
See product
sztucer z wylotem kwadratowym, NIAGARA Okragla Outlet with a square opening
NIAGARA Round - Pipes and Fittings
See product
NIAGARA stalowa Narożnik wewnętrzny Internal corner
NIAGARA Round gutters
See product
NIAGARA Stalowa - Narożnik zewnętrzny External corner
NIAGARA Round gutters
See product
NIAGARA Okragla - maskownica rynny Front fascia
NIAGARA Round - Grilles
See product
lacznik maskownicy czolowej NIAGARA Okragla Front Fascia Connector
NIAGARA Round - Grilles
See product
NIAGARA Stalowa - Rura spustowa Downpipe
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Sztucer Outlet
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Kolanko Elbow
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Okragla - wylewka Spout
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Obejma rury downpipe bracket
NIAGARA Round - Pipes and Fittings
See product
Clamp plate Clamp plate
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Łapacz deszczówki - czyszczak Rainwater catcher /cleaner
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Trójnik T-connection
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Trojnik redukcyjny 90/100, miniature 100/90 Reducing T-connection
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Łącznik rury Pipe connector
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Mufa pipe socket
NIAGARA Round - Pipes and Fittings
See product
Hooper head Hooper head
NIAGARA Round - Pipes and Fittings
See product
NIAGARA Stalowa - Śruby do obejmy Expansion plugs
NIAGARA Round - Pipes and Fittings
See product
Lakier zaprawkowy - NIAGARA Tytanium Touch-up paint
NIAGARA - Gutter accessories
See product
Gutter Gutter
NIAGARA Round - Gutters
See product
Gutter Gutter
NIAGARA Round - Gutters
See product
Gutter Gutter
NIAGARA Round gutters
See product
NIAGARA Square NIAGARA Square
A system of square metal gutters with a protective coating.
See product
Square Pipe – NIAGARA SQUARE Square Pipe – NIAGARA SQUARE
NIAGARA Square - Pipes and Fittings
See product
Niagara kwadratowa - rura Downpipe
NIAGARA Square - Pipes and Fittings
See product
NIAGARA Kwadratowa - Trójnik T-connection
NIAGARA Square - pipes and fittings
See product
NIAGARA Kwadratowa - Kolanko Elbow
NIAGARA Square - pipes and fittings
See product
NIAGARA Kwadratowa - Mufa pipe socket
NIAGARA Square - pipes and fittings
See product
NIAGARA Kwadratowa - Obejma rury downpipe bracket
NIAGARA Square - pipes and fittings
See product
Blaszka do obejmy Clamp plate
NIAGARA Square - pipes and fittings
See product
NIAGARA Kwadratowa - Śruby do obejmy Screws for brackets
NIAGARA Square - Accessories
See product
Listwa J - NIAGARA Kwadratowa J-bar
NIAGARA Square - Accessories / Flashings
See product
Slide paste Slide paste
NIAGARA - Gutter accessories
See product
Podbitka z blachy trapezowej TP-7 bez perforacji T-7P, unperforated
Trapezoidal Sheets Soffit
See product
Klej uszczelniacz dekarski do rynien i blach, Den Braven, miniature Roofing sealants
Roof and Gutter Accessories
See product

Articles

CSR, Sponsoring sportowy
The Academy of Crafts Continues to Grow—Paweł Francuz Named New Ambassador, Ryszard Piwowski Named Honorary Ambassador

The Academy of Crafts is embarking on the next phase of its activities. During the annual meeting in Sokołów, plans were made for upcoming training sessions, participation in trade shows and industry events, and other initiatives. The new Brand Ambassador, Paweł Francuz, also attended the meeting. Ryszard Piwowski, who has been associated with the Academy for many years, was named Honorary Ambassador.

Read more
Competitions, CSR, Sponsoring sportowy
2026 PGE Grand Prix — Ustka Once Again the Capital of Summer Volleyball

The 2026 PGE Grand Prix once again drew the best Polish volleyball teams to Ustka. The tournament, played in a 4x4 format, kicks off the 2026–2027 league season and combines athletic competition with the summer atmosphere of the Baltic Sea and attractions prepared for fans.

Read more
Business
Blachy Pruszyński Company is a partner of National Roofers' Day 2026

On July 24–25, the 26th National Roofers’ Day was held in Nałęczów. The event brought together roofers, manufacturers of roofing materials and roof accessories, and industry partners. This year’s celebration was also special because it marked the 25th anniversary of the Lublin Branch of the Polish Roofers’ Association.

Read more