blachodachowka panelowa modulowa VERONA wide
NEW

Verona - modular roof tile - panel

Verona – modular roof tile - panel roof tile with a beautiful symmetrical design and an elegant structure, thanks to the nanofala. Short lead time in anthracite (7016) and black (R033).

Technical specification

General information

Regle coverage in the form of single -water panels is produced in two excellent coatings: gloss polyurethane (5 colors) and matte polyurethane Purmat (6 colors).

This is the only coverage of this shape on the Polish market made of coated sheet, which makes them much cheaper to competitive panels with sprinkles. Low profile, and therefore a wide coverage (up to 1205 mm of effective width) make the selection of Regle panels even more economical.

Fast and uncomplicated assembly with coated nails guarantees an aesthetic finish.

length of module:
350 mm
height of bending:
30 mm
height of profile:
13 mm
effective width:
1134 mm
total width:
~1199 mm
min. slope of roof:
25°
VERONA RYSUNEK przekroj

Recommendations

Transport and storage

  • It is of course the best to unload in original manufacturer packaging, using mechanical unloading equipment.
  • Unloading shall be carried out by the proper number of people, that is in the case of long sheets (ca. 6  linear metre) the sheets shall be unloaded by 6 people, three on each side. Special attention shall be paid not to friction one sheet against one another, bend the side edges or stretch the sheet. Steel sheet deformation during the unloading and moving can result in problems with proper installation (chinks in clamps).
  • Galvanised and aluzinc steel sheets must be protected against getting wet!
  • If the customer collects the product  with his own means of transportation, the vehicle shall have an open loading platform allowing for easy loading and unloading, with the length suitable for ordered sheets. The sheets shall not extend beyond the platform. Proper anchoring of the sheet packages for the transport will reduce the damage of the sheet paint coat due to abrasion.

Maintenance and washing

  • In order to extend durability of roofs and elevations it’s recommended to check and conserve it.
  • Inspection – One time a year (best in spring) there should be inspection of roof/elevation for early detection of possible damage.
  • Cleaning of steel sheet – Roof and elevation made of steel sheets require cleaning at least once a year. Stratifying dirt on steel sheet may cause uneven discoloration of lacquer (because of uneven impact of UV beams), and lower protection to corrosion(dust traps humidity on steel sheets which causes damage). Dirty and stained spots can be cleaned by soft brush and water (temp. max. 60c). If it is necessary it is permitted to use some light detergent (ph 6/7, max 10% solution). There also can be used pressed water(max. 100bar) to cleaning, however the beam of water cannot be applicated too near of surface of sheets(min. 30 cm), also it shouldn’t be perpendicularly to surface. Near the connections water beam should be directed to bottom, to avoid water of entering cracks near connections. With old surfaces of steel sheets we should deal with high cautiously. Cleaning should be conducted from top to bottom, and cleaned spots should be rinsed out immediately.
  •  It is not permitted to use scouring powders, nitro solvent, chlorine liquor, aromatised substances, substances with amon chloride or sodium.
  • Damages – Possible damages during guarantee should be consulted with Contractor of roof/elevation and can be repaired only with his written permission.Repair of damages on small surfaces is done with quick-drying varnish. However painting big surfaces should be done with special industrial paints dedicated to renovating coverings. Painting should be limited only to special damaged spots (scratches to steel, centres of corrosion etc.)Preparation of surface to painting should be done with generally accepted rules. It is necessary to precisely remove all signs of corrosion – best with special brush or  close-grained sandpaper. Then that surface should be undusted, degreased and cleaned. To degrease extraction naptha or water with addition of surfactant(best with 1-2%solution of ammoniac) can be used. Repaired spots may be different in colour compared to original steel sheets because of natural impact of atmospheric phenomenon (ageing of varnish due to impact of UV radiation)
  • ATTENTION!– During inspecting, cleaning, conservation and repair all work safety regulations should be obeyed.Pruszyński Sp. z o.o. is not in charge of possible accidents during carrying out all following actions.

Assembly notes

Wooden grid:

  • It is recommended to use battens with a minimum cross-section of 40×50 mm (depending on the rafter spacing).
  • To construct the supporting structure, use:

    wooden battens with a cross-section of 40 x 50 mm or 40 x 60 mm,

    wooden counter-battens with a cross-section of 40 x 50 mm or 40 x 60 mm.

  • To create the sub-structure for the roof covering assembly, use dry construction wood of at least C24 or KVH class, impregnated with agents that do not cause corrosion of coated steel sheets.
  • Particular attention should be paid to the batten spacing measured from the same edges, which depends on the type of covering, as well as the even line of their assembly and the leveling of their plane.
  • The wooden batten sub-structure should guarantee a level and stable plane for the roof covering assembly! Counter-battens are used to fix the roof membrane (underlayment – FWK) to the rafters. Roof tile panels are fixed directly to the battens. The sub-structure prepared for the roof tile assembly should have a level plane and right angles of the roof slope.
  • Before spacing the battens, the module length must be measured. Remember that the measured module length follows the scheme below.

TIGRA Plus assembly:

  • Due to its asymmetrical shape and the applied capillary groove solution, TIGRA PLUS panel roof tile requires a traditional assembly method.
  • The capillary groove construction with side drainage in the TIGRA PLUS roof tile is an additional innovative protection that effectively drains rainwater on every roof tile module.
  • The applied solution and the asymmetrical shape of the roof tile profile require the contractor to follow the correct sequence of joining sheets by overlapping the covering rib onto the underlapping one (with the capillary groove) when assembling from right to left. Assembly from left to right, as well as from the bottom to the top of the slope and in the opposite direction, is also permitted. Remember to maintain the correct sequence of sheets in accordance with the rainwater flow direction.
  • Remember to use self-drilling 4.8 x 20 mm stitcher screws for joining sheets and 4.8 x 35 mm assembly screws.

For more assembly details, refer to the assembly instructions available on our website in the downloads section, under the Contractor profile.

Choose a coating:
Więcej informacji o powłokach
PURMATpolyurethane, matt

Technical specification of the coating

thickness of coating
50 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★★
possibility of bending
High ★★★☆
Aesthetic warranty
up to 30 years
technical warranty
50 years

Available colours

PUM RR 033
PUM R033
PUM RAL 7016
PUM RAL 7016
TOPMAT®polyester matt (Arcelor DE)

Technical specification of the coating

thickness of coating
35 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★☆
possibility of bending
High ★★★☆
Aesthetic warranty
20 years
technical warranty
35years

Available colours

TOPMAT RR 033
TOPMAT R033
TOPMAT RAL 7016
TOPMAT RAL 7016
Pruszyński Company guarantess delivery of each order in one colour shade. Although there is possibility for occuring small differences in colour shade in different product batches due to technological process of covering steel sheets with paint.

Regarding this please inform sales person if an order is a continuation of a previous batch.

Product description

Blachodachowka panelowa VERONA

The beauty of symmetry. Verona panel roof tile

An excellent proposal for an investor who appreciates modern and non-obvious design. NEWVERONA panel roof tile.

Panel/ modular roof tile, VERONA, is another pattern from the family of flat roof tiles. The main inspiration for its profile were flat roof tiles, which are exceptionally popular among our clients who value minimalist design. Additionally, we utilized the experience gathered during the development and optimization of the profile for such roof coverings as TP26 SUPER or standing seam panels.

The result of these works is an exceptionally interesting and unique panel roof tile with a geometric and harmonious shape, which simultaneously offers high utility values. VERONA is available only in the nanofala variant, well known to our customers from our other products.

Nanofala is an extremely popular solution among our clients, which was previously implemented in the standing seam panel or TIGRA roof tile and proved to be a total hit. The waves are discreet enough to look like a flat surface from a distance, while simultaneously strengthening the panel and improving its stiffness.

As with every roof covering, ventilation of the roof slope is extremely important in the case of VERONA panel roof tile. Proper ventilation prevents degradation, damage, and even leaking of the roof slope. Our offer includes a wide range of roof accessories and additions that improve ventilation.

See our offer of accessories

Choose the best accessories for your roof!

Kalenica Prosta: TYP1 (duża) PLAIN Ridge: large
Typical metal sheet workings
See product
Wkręty samowiercące typu TORX TORX self-drilling screws (staples)
Fasteners for trapezoidal sheets, roof tiles, karo panels (short)
See product
Niagara stalowa - rynna Gutter
NIAGARA Steel- gutter
See product
Podbitka TP-7P - z perforacją TP-7P with perforation
Soffit made of trapezoidal sheet
See product