Blachodachowka modulowa TIGRA plus

Tigra Plus - Modular roof tile - panel

TIGRA Plus: panel roof tile (modular) that combines the beauty of a modern roof with a new standard of tightness and safety.

Technical specification

General information

A capillary groove with lateral drainage ensures extraordinary tightness and safety of the roof against leakage. The applied technical solution, the asymmetrical shape of the panel roof tile profile, forces the contractor to follow the correct order of joining sheets by overlapping the capping ridge onto the base ridge (with the capillary groove) when performing assembly from right to left.

Module length:
350 mm
Growing height:
30 mm
Profile height:
11,5 mm
usable width:
1145 m
Total width:
~1186 mm
min. slope
25°
Blachodachowka panelowa TIGRA Plus rys techniczny

Recommendations

Transport and storage

  • It is of course the best to unload in original manufacturer packaging, using mechanical unloading equipment.
  • Unloading shall be carried out by the proper number of people, that is in the case of long sheets (ca. 6  linear metre) the sheets shall be unloaded by 6 people, three on each side. Special attention shall be paid not to friction one sheet against one another, bend the side edges or stretch the sheet. Steel sheet deformation during the unloading and moving can result in problems with proper installation (chinks in clamps).
  • Galvanised and aluzinc steel sheets must be protected against getting wet!
  • If the customer collects the product  with his own means of transportation, the vehicle shall have an open loading platform allowing for easy loading and unloading, with the length suitable for ordered sheets. The sheets shall not extend beyond the platform. Proper anchoring of the sheet packages for the transport will reduce the damage of the sheet paint coat due to abrasion.

Maintenance and washing

  • In order to extend durability of roofs and elevations it’s recommended to check and conserve it.
  • Inspection – One time a year (best in spring) there should be inspection of roof/elevation for early detection of possible damage.
  • Cleaning of steel sheet – Roof and elevation made of steel sheets require cleaning at least once a year. Stratifying dirt on steel sheet may cause uneven discoloration of lacquer (because of uneven impact of UV beams), and lower protection to corrosion(dust traps humidity on steel sheets which causes damage). Dirty and stained spots can be cleaned by soft brush and water (temp. max. 60c). If it is necessary it is permitted to use some light detergent (ph 6/7, max 10% solution). There also can be used pressed water(max. 100bar) to cleaning, however the beam of water cannot be applicated too near of surface of sheets(min. 30 cm), also it shouldn’t be perpendicularly to surface. Near the connections water beam should be directed to bottom, to avoid water of entering cracks near connections. With old surfaces of steel sheets we should deal with high cautiously. Cleaning should be conducted from top to bottom, and cleaned spots should be rinsed out immediately.
  •  It is not permitted to use scouring powders, nitro solvent, chlorine liquor, aromatised substances, substances with amon chloride or sodium.
  • Damages – Possible damages during guarantee should be consulted with Contractor of roof/elevation and can be repaired only with his written permission.Repair of damages on small surfaces is done with quick-drying varnish. However painting big surfaces should be done with special industrial paints dedicated to renovating coverings. Painting should be limited only to special damaged spots (scratches to steel, centres of corrosion etc.)Preparation of surface to painting should be done with generally accepted rules. It is necessary to precisely remove all signs of corrosion – best with special brush or  close-grained sandpaper. Then that surface should be undusted, degreased and cleaned. To degrease extraction naptha or water with addition of surfactant(best with 1-2%solution of ammoniac) can be used. Repaired spots may be different in colour compared to original steel sheets because of natural impact of atmospheric phenomenon (ageing of varnish due to impact of UV radiation)
  • ATTENTION!– During inspecting, cleaning, conservation and repair all work safety regulations should be obeyed.Pruszyński Sp. z o.o. is not in charge of possible accidents during carrying out all following actions.

Assembly notes

Wooden grid:

  • It is recommended to use battens with a minimum cross-section of 40×50 mm (depending on the rafter spacing).
  • To construct the supporting structure, use:

    wooden battens with a cross-section of 40 x 50 mm or 40 x 60 mm,

    wooden counter-battens with a cross-section of 40 x 50 mm or 40 x 60 mm.

  • To create the sub-structure for the roof covering assembly, use dry construction wood of at least C24 or KVH class, impregnated with agents that do not cause corrosion of coated steel sheets.
  • Particular attention should be paid to the batten spacing measured from the same edges, which depends on the type of covering, as well as the even line of their assembly and the leveling of their plane.
  • The wooden batten sub-structure should guarantee a level and stable plane for the roof covering assembly! Counter-battens are used to fix the roof membrane (underlayment – FWK) to the rafters. Roof tile panels are fixed directly to the battens. The sub-structure prepared for the roof tile assembly should have a level plane and right angles of the roof slope.
  • Before spacing the battens, the module length must be measured. Remember that the measured module length follows the scheme below.

TIGRA Plus assembly:

  • Due to its asymmetrical shape and the applied capillary groove solution, TIGRA PLUS panel roof tile requires a traditional assembly method.
  • The capillary groove construction with side drainage in the TIGRA PLUS roof tile is an additional innovative protection that effectively drains rainwater on every roof tile module.
  • The applied solution and the asymmetrical shape of the roof tile profile require the contractor to follow the correct sequence of joining sheets by overlapping the covering rib onto the underlapping one (with the capillary groove) when assembling from right to left. Assembly from left to right, as well as from the bottom to the top of the slope and in the opposite direction, is also permitted. Remember to maintain the correct sequence of sheets in accordance with the rainwater flow direction.
  • Remember to use self-drilling 4.8 x 20 mm stitcher screws for joining sheets and 4.8 x 35 mm assembly screws.

For more assembly details, refer to the assembly instructions available on our website in the downloads section, under the Contractor profile.

Choose a coating:
Protective coatings
PURMATpolyurethane, matt

Technical specification of the coating

Thickness of coating
50 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High ★★★☆
Aestetic warranty
30 years
Technical warranty
50 years

Available colours

PUM R011
PUM R011
PUM R028
PUM R028
PUM RR 033
PUM R033
PUM RR 750
PUM R750
PUM RAL 7016
PUM RAL 7016
PUM RAL 8017
PUM RAL 8017
PURLAKpolyurethane, glossy

Technical specification of the coating

Thickness of coating
50 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★☆
Possibility of bending
High ★★★☆
Aestetic warranty
30 years
Technical warranty
50 years

Available colours

PU RAL 7016
PU RAL 7016
PU RAL 9005
PU RAL 9005
TOPMAT®poliyester, matt (Arcelor DE)

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High ★★★☆
Aestetic warranty
20 years
Technical warranty
35 years

Available colours

TOPMAT RR 033
TOPMAT R033
TOPMAT R750
TOPMAT R750
TOPMAT RAL 7016
TOPMAT RAL 7016
TOPMAT RAL 8017
TOPMAT RAL 8017
ULTRAMAT®poliyester, matt (Arcelor PL)

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High ★★★☆
Aestetic warranty
15 years
Technical warranty
35 years

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PS25poliyester, glossy

Technical specification of the coating

Thickness of coating
25 µm
Corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
Possibility of bending
Good ★★☆☆
Aestetic warranty
10 years
Technical warranty
30 years

Available colours

R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 7035
RAL 7035
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9002
RAL 9002
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
The PRUSZYŃSKI company guarantees the execution of each order in the same color (shade). However, due to the complexity of the coating processes, there may be differences in shades between individual deliveries.

Responsibility for the color is therefore limited to one delivery only.

In connection with the above, in the case of ordering sheets for a specific batch, please indicate on the order or inform the Trader that it is a continuation of the order and the delivery of a color sample.

In order to ensure color consistency of sandwich panels with other elements, such as flashings, they should be ordered from one supplier.

Product description

Dom jednorodzinny, blachodachowka TIGRA

Roofing tile with character

Panel roof tile TIGRA PLUS is a unique combination of a modern flat profile with a subtle nanowafe, giving the roof covering an elegant and timeless look. Its geometric lines and proportions make it perfectly compatible with both classic building architecture and its modern forms.

To meet the growing demands of investment products and contractors, the TIGRA PLUS profile has undergone a precise facelift. The result of cooperation between roofing experts and engineers is the application of an innovative capillary groove with lateral drainage at the bottom of each module.

As with any roof covering , correct assembly and ventilation of the roof slope are extremely important for the TIGRA PLUS panel roof tile. Check more on VENTILATION. Our offer includes a wide range of roof accessories and additives that improve ventilation.

Others in this category

blachodachowka panelowa modulowa VERONA NEW Verona
Modular roof tile - panel
See product
Blachodachowka FIORD Fiord
Modular roof tile - panel
See product
Blachodachowka PLASKA Flat
Modular roof tile - panel
See product
Blachodachowka PLASKA PLUS Flat PLUS
Modular roof tile - panel
See product
Regle - Blachodachówka modułowa - panelowa Regle
Modular roof tile - panel
See product
Blachodachowka panelowa MODUS Modus
Modular roof tile - panel
See product
Loara - Blachodachówka modułowa - panelowa Loara
Modular roof tile - panel
See product
Blachodachowka REN Ren
Modular roof tile - panel
See product
Szafir Szafir
Modular roof tile - panel
See product

Discover our offer of accessories

Choose the best accessories for your roof!