Pas nadrynnowy TYP2

Over-gutter flashing with hem

The OVER-GUTTER flashing belongs to the eave flashings, placed along the lower edge of the roof (eave). It is made of galvanized sheet, 0.5mm thick, covered with a protective coating. Designed for standing seam panels, with additional perforation for improved ventilation.

Technical specification

General information

The gutter flashing, often also referred to as KAPINOS, is an element of the roof covering, responsible for draining water from the roof slope to the gutter. In addition, it protects the front strip and the wall of the building against rain, especially during heavy rainfall. Depending on the selected roofing, you can choose the most suitable variant of the gutter flashing. In our offer you will find: Gutter flashing: TYPE 1 - universal for metal roof tiles and panel metal roof tiles Gutter flashing: TYPE2 - for seam PANELS Gutter flashing: TYPE 3 - for seam PANELS with additional perforation gutter flashing: TYPE4 - for REGELE or FLAT and FLAT plus metal roof tiles Gutter flashing: TYP5 - a slightly different variant dedicated to REGLE, FLAT or FLAT PLUS metal roof tiles The TYP2 variant has been designed especially for seam PANELS. This shape is available in two varieties - classic and with perforation, providing additional ventilation of the roof sheet.

Length:
2 m
Thickness:
0,50
Coating
polyester glossy / polyester mat / polyurethane / zink / aluzinc
Pas nadrynnowy TYP2 - przekroj
Choose a coating:
Protective coating
PURMATpolyurethane, matt

Technical specification of the coating

Thickness of coating
50 µm
Corrosion resistance
High ★★★★
UV resistance
High★★★★
Possibility of bending
High ★★★☆
Aesthetic guarantee
30 years
Technical guarantee
50 years

Available colours

PUM R011
PUM R011
PUM R028
PUM R028
PUM RR 033
PUM R033
PUM RR 750
PUM R750
PUM RAL 7016
PUM RAL 7016
PUM RAL 8017
PUM RAL 8017
PURLAKpolyurethane, glossy

Technical specification of the coating

Thickness of coating
50 µm
Corrosion resistance
High★★★★
UV resistance
High ★★★☆
Possibility of bending
High ★★★☆
Aesthetic guarantee
30 years
Technical guarantee
50 years

Available colours

PU RAL 7016
PU RAL 7016
PU RAL 9005
PU RAL 9005
TOPMATpoliyester, matt (Arcelor PL)

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High★★★☆
Aesthetic guarantee
20 years
Technical guarantee
35 years

Available colours

TOPMAT RR 033
TOPMAT R033
TOPMAT R750
TOPMAT R750
TOPMAT RAL 7016
TOPMAT RAL 7016
TOPMAT RAL 8017
TOPMAT RAL 8017
ULTRAMAT®poliyester, matt (Arcelor DE)

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★★
UV resistance
High ★★★★
Possibility of bending
High ★★★☆
Technical guarantee
20 years

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PMG35®poliyester, matt

Technical specification of the coating

Thickness of coating
35 µm
Corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
Possibility of bending
Good ★★☆☆
Aesthetic guarantee
15 years
Technical guarantee
35 years

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PS25poliyester, glossy

Technical specification of the coating

Thickness of coating
25 µm
Corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
Possibility of bending
Good ★★☆☆
Aesthetic guarantee
10 years
Technical guarantee
30 years

Available colours

R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 7035
RAL 7035
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9002
RAL 9002
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
Metallic coatings

Technical specification of the coating

Available colours

powłoka AZ - aluzynk
AZ – aluzinc
Powłoka - OC - ocynk
OC – galvanized
Pruszyński Company guarantess realization of each order in one colour shade. Although due to technological process of covering paint to steel shets there is possibility for occuring difference in colour shade in different deliveries.

Regarding this please inform sales person if different delivery is continuation of previous orders.
schemat domu, dachy, obrobki blacharskie

EAVE flashings

Eaves flashings are one of the most important technical details of a roof, responsible not only for the aesthetic finishing of the slope edges, but above all for the proper functioning of the entire roofing system.

The most important tasks of eaves flashings include:

  • effective drainage of rainwater and meltwater into the gutter system,
  • protecting the roof layers against capillary rising,
  • protection of the eaves structure, fascia board, and facade against moisture,
  • ensuring the tightness of the roofing in the eaves area,
  • protecting the slope against wind-blown rain, snow, and strong winds,
  • ensuring proper ventilation of the roof slope,
  • drainage of condensate and moisture from the initial covering layer,
  • increasing the durability and operational safety of the roof.

Particular attention should be paid to the correct connection of eaves flashings with the roof membrane, gutter system, and ventilation elements. An incorrectly executed eaves detail can lead to moisture in the thermal insulation, degradation of the wooden structure, and limited effectiveness of the roof slope ventilation.

Over-gutter flashing with hem

The OVER-GUTTER flashing, often also referred to as a DRIP EDGE, is a roofing element responsible for draining water from the roof slope into the gutter. Its main role is to ensure the flowing water detaches from the slope and is redirected into the gutter. An additional element in the form of a so-called “hem” enables easy installation of standing seam panels and single-module roof tiles. Furthermore, special two-row ventilation improves air circulation under the roofing. Our offer includes a wide range of over-gutter flashings, including, among others, OVER-GUTTER flashings:

See our offer of related products

Blachodachowka RUBIN Rubin
Custom -made metal roof tile
See product
Blachodachowka OPTIMA Optima
Custom -made metal roof tile
See product
Regle - Blachodachówka modułowa - panelowa Regle
Modular roof tile - panel
See product
Niagara kwadratowa - rynna Gutter
NIAGARA Square - gutters
See product
Taśma kalenicowa Ridge tape
Roof accessories
See product