Listwa podkalenicowa

Under-ridge strip

Ventilation flashing, installed under the ridge. Recommended for standing seam panels and modular roof tiles. Available in polyester coatings and two standard lengths – 0.5 rm and 2.0 rm.

Technical specification

General information

We offer three types of under-ridge strips. All of them perform the same function but are tailored to different roof coverings. Their tasks are:

1. Provide properly functioning ventilation thanks to ventilation openings of the appropriate surface area – the outlet ventilation gap should have an effective area four times smaller than the inlet gap, measured per one side of the roof slope – in accordance with the DIN 4108 standard; min. 50 cm²/lm. This solution ensures the appropriate pressure difference that forces increased air movement under the roofing metal sheets.
2. Ensure tightness – acting as a barrier against loose snow and light rain blown under the ridge flashings (the so-called ridge cap).
3. Act as a load-bearing element for ridge flashing assembly – the strip should be mounted to the roof covering using stitch screws on both sides of the roof slope in a straight line. Using the same screws (stitch screws) in a color matched to the color of the roof covering, the ridge flashings must be installed. It is also recommended to use ridge tapes with mesh to ensure the highest level of protection regarding tightness, especially in the case of hip ridges.

Length:
2 m
Thickness:
0,50
Coating
polyester gloss / polyester mat / polyurethane
Listwa podkalenicowa - przekroj

Under-ridge strips application table

The Blachy Pruszyński offer includes 3 types of under-ridge strips – Standard, TP-26 SUPER, and for flat roof tiles. The first one is applied to PD510 standing seam panels, KARO panels, and single-module flat roof tiles. The second one is designed for the TP-26 SUPER trapezoidal sheet – its design allows for installation without the need to cut the strip at the ribs of the trapezoid, and its width corresponds to the width of the sheet. The third option is the under-ridge strip for flat roof tiles – VERONA, PŁASKA, PŁASKA PLUS, and REGLE.

NOTE: detailed installation recommendations can be found in the dedicated installation instructions in the downloads section >> Installation instructions (available in the contractor and distributor profiles).



Under-ridge strip (basic)
System Lenght
Single-module flat roof tiles FLAT, FLAT PLUS, REGLE2,0 m
System Lenght
PD-510 standing seam panels0,5 m | 2,0 m
KARO Panels2,0 m
Under-ridge strip TP26
System Lenght
TP-26 SUPER trapezoidal sheet1,109 m
Under-ridge strip for flat roof tiles
System Lenght
Under-ridge stSingle-module flat roof tiles FLAT, FLAT PLUS, REGLErip for flat roof tiles2,0 m
Choose a coating:
Protective coatings
PMG35®Polyester mat

Technical specification of the coating

coating thickness
35 µm
corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
Possibility of processing
Good ★★☆☆
Aesthetic warranty
15 years
technical warranty
35 years

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PS25Polyester glossy

Technical specification of the coating

Available colours

RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
Pruszyński Company guarantess realization of each order in one colour shade. Although due to technological process of covering paint to steel shets there is possibility for occuring difference in colour shade in different deliveries.

Regarding this please inform sales person if different delivery is continuation of previous orders.

Product description

Under-ridge strip

VENTILATION FLASHINGS

VENTILATION FLASHINGS play an extremely important role in ensuring the long-term and trouble-free use of the roof. They are responsible for the correct ventilation of the roof slope, i.e., the free flow of air under the covering, thanks to which the covering naturally gets rid of moisture that accumulates on the inner side of the covering and, as a result of the condensation phenomenon, turns into water and moisture. In the long term, this moisture causes irreversible damage both to the roof framing and can also cause damage to the covering itself.

Under-ridge strip

The under-ridge strip is a special flashing dedicated to the installation of PD-510 standing seam panels and modular roof tiles. For these coverings, the installation of the ridge cap (also known as “gąsior”) is performed on a so-called intermediate flashing – specifically the under-ridge strip. This strip is also colloquially called the under-cap strip, following the customary name of this element.

We offer the under-ridge strip in two lengths:

  • 2000 mm – recommended for the installation of diagonal ridges with PD-510 standing seam panels, as well as for the installation of KARO panels and modular roof tiles.
  • 500 mm – perfectly suited for standing seam panels.

See our offer of accessories

Panel-PD510-Nano Panel PD510 Nano
Roof panels with standing seam
See product
Blachodachowka panelowa REGLE Regle
Modular roof tile - panel
See product
Panel-PD510-F-N Panel PD510 F-N
Roof panels with standing seam
See product
Panel-PD510-T-S Panel PD510 T-S
Roof panels with standing seam
See product
Blachodachowka PLASKA Flat
Modular roof tile - panel
See product