Karta produktu
PWS2 -MW -ST -80 – wall sandwich panel – mineral wool – visible fastening
![]() |
||||||||||||
![]() PWS2 -MW -ST -80 - wall sandwich panel - mineral wool - visible fasteningTechnical specificationGeneral informationThe PWS2 -MW layered plate is a new, improved generation of our product -rated product - a layered plate with a core of mineral wool. A product accident intended for wall mounting, our offer includes two variants - a plate with a visible lock and a plate with a hidden lock. Basic features of the product, wall plate, layered with a core of mineral wool, with a visible lock, 80 mm thick and a density of 115 kg / m3: M core
mineral wool
thickness of panel
80 mm
effective width
1150/1000 mm
total width
1170/1020 mm
weight 1m2
17,05 kg
min length of panel
2,0 mb
max length of panel
see Length of panels
thickness of steel sheets
0,5 - 0,7 mm
type of exterior profilation
trapezoidal - Tmicro-trapezoidal - M wave - F nano-wave - N flat - P * type of interior profilation
trapezoidal - Tflat - P coverings
polyesther glossy/mat, polyurethane, HPS200, aluzinc
Physical propertiesDeclared core thermal conductivity coach - [W/mk]
0,041
UC heat transfer coefficient - [W/m2K]
NPD
UDS thermal insulation [W/m2K]
NPD
fire spread / reaction to fire
NRO / A2-s1, d0
fire resistance
NPD
Sound absorption (αw)
NPD
Length of panelThe table below has a classification divided into color groups for individual colors available in the assortment of Pruszyński Sp. z o.o permissible panel lengths depending on the color of the cladding (minimum length - 2.5 MB) for single -span systems. group I (very bright colors)Maximum length 18 m wall / 18 m roof ![]()
RAL 9001*
![]()
RAL 1015
![]()
RAL 7035
![]()
RAL 9002
![]()
RAL 9010
group II (bright colors)Maximum length 12 m wall / 12 m roof ![]()
RAL 9022*
![]()
RAL 7040*
![]()
RAL 7037*
![]()
RAL 6033*
![]()
RAL 6021*
![]()
RAL 6018*
![]()
RAL 5024*
![]()
RAL 5018*
![]()
RAL 5012*
![]()
RAL 2009*
![]()
RAL 2008*
![]()
RAL 2004*
![]()
RAL 2003*
![]()
RAL 2000*
![]()
RAL 1035*
![]()
RAL 1023*
![]()
RAL 1019*
![]()
RAL 1017*
![]()
RAL 1014*
![]()
RAL 1004*
![]()
RAL 1003*
![]()
RAL 1002
![]()
RAL 1021
![]()
RAL 7000
![]()
RAL 9006
SILVER group III (dark colors)Maximum length 9 m wall / 9 m roof ![]()
RAL 7022*
![]()
RAL 7015*
![]()
RAL 6020*
![]()
RAL 6011*
![]()
RAL 6003*
![]()
RAL 6000*
![]()
RAL 5022*
![]()
RAL 50011*
![]()
RAL 5009*
![]()
RAL 5005*
![]()
RAL 5002*
![]()
RAL 3013*
![]()
RAL 3003*
![]()
RAL 3002*
![]()
RAL 3000*
![]()
RAL 8016
![]()
PUM RR 028
![]()
PMG RR 033
![]()
PMG RR 028
![]()
PMG RR 750
![]()
PMG RR 011
![]()
PM Dark Walnut
![]()
Golden Oak
![]()
RAL 3011
![]()
RAL 3005
![]()
RAL 8023
![]()
RAL 6005
![]()
RAL 6029
![]()
RAL 5010
![]()
RAL 9005
![]()
RAL 8017
![]()
RAL 7016
![]()
RAL 7024
![]()
RAL 9007
SILVER METALLIC ATTENTION! Considering that dark colors from group III are subject to much larger thermal loads than boards in very light and light colors from group I and II should be assessed depending on the loads, what plates system on the wall is possible to be used. * The colors marked with the star are not available in the standard offer. Please direct individual queries in terms of colors using the contact form. Read more below. Recommendations for the selection of plates in the context of thermal loadsATTENTION- III group – dark colours Taking in consideration that dark colours from group III has much bigger thermal load and very bright and bright colours from groups I and II, there should be paid special attention during projecting and below conditions are complained:
* For panels with dark colours recommended are single-span schemes; in other case there may occur non-acceptable by Investor strains on external claddings on panels on intermediate supports. Flutings which may occur, complain with norm PN EN 14509 due to acceptable deviation, but may be topic of complaints. ** Maximum length of panels should be in accordance of producer’s guidelines due to type and use of panels – see LENGTH OF PANELS *** Assembly of panels with dark colours is possible within temperatures 10oC to 35oC. This condition is essential and must be strictly observed. Assembly of panels in very bright and bright colours is possible within range of temperatures from +5oC to +35oC Transport recommendationsRecommended ways of transport for sandwich panels:
StorageSandwich panels should be storage maximum 2 packages one on another. In below chart you can see what is maximal quantity of panels in one package.
All packages should be storage on flat surface with possibility to discharging water.
MaintenanceIn order to extend durability of roofs and elevations it’s recommended to check and conservative it.
ATTENTION!
Pruszyński Sp. z o.o. is not in charge of possible accidents during carrying out all following actions. Polyester glossy
Technical specification of the coatingthickness of coating
25 µm
corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
possibility of bending
Good ★★☆☆
Available colours![]()
RR 032
![]()
RAL 1002
![]()
RAL 1015
![]()
RAL 1021
![]()
RAL 3005
![]()
RAL 3011
![]()
RAL 7016
![]()
RAL 3016
![]()
RAL 5010
![]()
RAL 6005
![]()
RAL 6029
![]()
RAL 7000
![]()
RAL 7024
![]()
RAL 7035
![]()
RAL 8004
![]()
RAL 8017
![]()
RAL 8023
![]()
RAL 9002
![]()
RAL 9005
![]()
RAL 9006
SILVER ![]()
RAL 9007
SILVER METALLIC ![]()
RAL 9010
![]()
Golden Oak
Polyester mat PM 35um
Technical specification of the coatingthickness of coating
35 µm
corrosion resistance
Wysoka ★★★☆
UV resistance
Dobra ★★☆☆
possibility of bending
Dobra ★★☆☆
Available colours![]()
PMG RR 750
![]()
PMG RR 011
![]()
PMG RR 028
![]()
PMG RR 032
![]()
PMG RR 033
![]()
PMG RAL 7016
![]()
PMG RAL 8017
![]()
PM Dark Walnut
PURLAK
Technical specification of the coatingthickness of coating
50 µm
corrosion resistance
Wysoka ★★★★
UV resistance
Wysoka ★★★☆
possibility of bending
Wysoka ★★★☆
Available colours![]()
PU RR 028
![]()
PU RAL 7016
![]()
PU RAL 8004
![]()
PU RAL 8017
![]()
PU RAL 9005
PURMAT
Technical specification of the coatingthickness of coating
50 µm
corrosion resistance
Wysoka ★★★★
UV resistance
Wysoka ★★★★
possibility of bending
Wysoka ★★★☆
Available colours![]()
PUM RR 750
![]()
PUM RR 011
![]()
PUM RR 028
![]()
PUM RR 033
![]()
PUM RAL 7016
![]()
PUM RAL 8017
AZ - aluzinc
Technical specification of the coatingAvailable colours![]()
AZ – aluzynk
Product description![]() Wall layered panels are used especially in indoor, industrial and public construction (shopping centers, warehouse centers, sports halls, etc.). In addition to the cover walls, the plates are used as: partition walls and as load -bearing walls in small transportable cold stores, in buildings of construction and in farm buildings. The rich color palette and the diverse shape of disc profiling enables the implementation of a number of interesting objects. The plates can be mounted both vertically and horizontally. Tags |
||||||||||||