Technical specification

General information

* Flat outer profile (P), only available from sheet gubmia above 0.6 mm

core
mineral wool
thickness of panel
100 mm
effective width
1050/1000 mm
total width
1106/1056 mm
weight 1m2
20,05 / 20,6 kg
min length of panel
2,0 mb
max length of panel
see length of panels
thickness of steel sheets
0,5 – 0,7 mm
type of exterior profilation
trapezoidal - T
micro trapezoidal - M
wave - F
nano-wave - N
flat – P*
type of interior profilation
trapezoidal - T
flat – P*
coverings
polyesther glossy/mat, polyurethane, HPS200, aluzinc
płyta warstwowa wełniana z ukrytym zamkiem 100

Recommendations

Transport recommendations

Recommended means of transport for sandwich panels:

  • truck (tractor tractor + semi -trailer with a length not shorter than the length of the loaded plates) with an open semi -trailer or enabling side loading on its entire length
  • The weight of the load may not exceed the permissible load capacity of the set,
  • Transport belts should be placed on a load at a distance of max. Every 3 m, but not less than 2 belts per package – belt tension cannot cause deformation of the plates.

Storage

Layered boards should be stored in packages (posts), it is allowed to store a maximum of two packages one on top of
The following table is given max. The number of discs that can be arranged in one package.

Panel thickness PWS
60 mm 18 pcs
80 mm 14 pcs
100 mm 11 pcs
120 mm 9 pcs
140 mm 8 pcs
160 mm 7 pcs
180 mm 6 pcs
200 mm 5 pcs
220 mm 5 pcs
240 mm 4 pcs
260 mm 4 pcs

 

  • It is recommended to store plates on an even surface (square, hall) on joists or polystyrene sleepers, which must be set up a maximum of 2.5 m (with plates with a total length of up to 2.5 m, use min. 3 foundations).
  • It is allowed to store a maximum of two panel packages up to 6MB one on the other, in the case of board packages above MB should be stored individually. All panel packages must be stored on an equal surface with the possibility of draining water.
  • When storing panels on the construction site, they should be protected against mechanical damage, exposure to UV rays, an aggressive environment (acids, fertilizers, salts and other corrosion factors), atmospheric precipitation, strong wind and others.
  • It is recommended to store parcels under roofing in ventilated rooms
  • Storage of plates should be carried out on an equal surface (square, hall) on joists, polystyrene or wooden foundations, which must be set up a maximum of 2.5 m (with plates with a total length of up to 2.5 m should be used at least 3 foundations ).
  • Protective films are used to additional protecting the surfaces of the plates against mechanical damage, stresses and impacts that can occur during transport or transhipment. Foils never release from the obligation to properly protect the plates during storage.
  • It is recommended to remove protective foil against attachment of elements on the facade or roof of the building. The foil should be removed at positive air temperatures, because at negative temperatures the adhesive is stratified and some of its components may remain on the baking tray.
  • Incorrect way of storing sheets can cause difficulties in removing protective film and leave glue traces on the surface of the plates. In such cases, complaints on the remains of glue after protective film will not be included by the manufacturer.
  • In the case of hidden fastening panels, pay attention that the foil is removed from the inside of the longer lock before assembly.

ATTENTION !!!

In the case of wall panels with visible fastening, the upper side of the panels in the package is a facade side, which should be paid special attention!

Maintenance and washing

In order to extend the durability period of roofs and facades made of coated sheets, they should be regularly controlled and preserved.

  • Review -once a year (preferably in spring), a roof/facade review should be reviewed to detect any damage early.
  • Cleaning sheet metal -roofs/facades made of coated sheet require cleaning at least once a year. Driving dirt can cause uneven discoloration of the color (result of uneven UV interaction), as well as to reduce corrosion resistance (dirt stops moisture on a baking tray gradually damaging it). Dodged and stained places can be cleaned with a soft brush and water (max. 60 ° C). If it is necessary, it is allowed to add a mild detergent to the water (pH 6 ÷ 7, max. 10% solution). Water under pressure (max. 100 bar) can also be used for cleaning, however, the water stream cannot be used too close to the surface of the plate (min. 30 cm), and it cannot be directed perpendicular to the surface. At the connectors, the water stream should be directed down to avoid entering the water under pressure into the gaps around the connectors. With old plate coatings, you should handle with exceptional caution. Washing should be carried out from top down and always cleaned place should be rinsed thoroughly with clean water.
  • Do not use scrubbing powders, nitro solvents, chloride solutions, aromatic agents, as well as salmiak (ammonium chloride) or sodium salts.
  • Damage -possible damage during the warranty period must be consulted with the roof/facade contractor and can only be performed with his written consent. Repair of damage on small surfaces is carried out with the help of varnishes for air -drying repairs, while painting large surfaces is, as a rule, only using special industrial paints adapted to renovation of coverings. The surface for painting should be limited only to the places requiring (scratches to the metal layer, corrosion focus, etc.). Preparation of the surface for painting should be made according to generally accepted rules. Always remove all traces of corrosion – preferably with special brushes or fine -grained sandpaper. Then the repaired surface needs to be thoroughly reproduced, degreased and cleaned. For degreasing the surface, you can use extraction gasoline or water with the addition of surface-leisure (preferably with the addition of 1-2% of the ammonia solution). The repaired zones can show color differences compared to the original colors of sheet metal due to the natural impact of atmospheric phenomena (aging of varnish under the influence of UV radiation).
  • Note- during review, cleaning, maintenance and repair, it is absolutely necessary to observe the health and safety rules.

Pruszyński Sp. z o.o. He is not responsible for any accidents arising from the above -mentioned activities.

Choose a coating:
Protective coatings
PURMATpolyurethane, matt

Technical specification of the coating

thickness of coating
50 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★★
possibility of bending
High ★★★☆

Available colours

PUM R011
PUM R011
PUM R028
PUM R028
PUM RR 033
PUM R033
PUM RR 750
PUM R750
PUM RAL 7016
PUM RAL 7016
PUM RAL 8017
PUM RAL 8017
PURLAKpolyurethane, mat

Technical specification of the coating

thickness of coating
35 µm
corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
possibility of bending
Good ★★☆☆

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PMG35®Polyester, mat

Technical specification of the coating

thickness of coating
35 µm
corrosion resistance
High ★★★☆
UV resistance
Dobra ★★☆☆
possibility of bending
Dobra ★★☆☆

Available colours

PMG R011
PMG R011
PMG R028
PMG R028
PMG R032
PMG R032
PMG R033
PMG R033
PMG R750
PMG R750
PMG RAL 7016
PMG RAL 7016
PMG RAL 8017
PMG RAL 8017
PS25polyester, glossy

Technical specification of the coating

thickness of coating
25 µm
corrosion resistance
High ★★★☆
UV resistance
Dobra ★★☆☆
possibility of bending
Dobra ★★☆☆

Available colours

R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3011
RAL 3011
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 7035
RAL 7035
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9002
RAL 9002
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
R028
R028
R032
R032
RAL 1002
RAL 1002
RAL 1015
RAL 1015
RAL 1021
RAL 1021
RAL 3000 probka koloru
RAL 3000
RAL 3005
RAL 3005
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6005
RAL 6005
RAL 6029
RAL 6029
RAL 7000
RAL 7000
RAL 7016
RAL 7016
RAL 7024
RAL 7024
RAL 7035
RAL 7035
RAL 8004
RAL 8004
RAL 8017
RAL 8017
RAL 9002
RAL 9002
RAL 9005
RAL 9005
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
RAL 1002
RAL 1002
RAL 3011
RAL 3011
RAL 3016
RAL 3016
RAL 5010
RAL 5010
RAL 6029
RAL 6029
RAL 7016
RAL 7016
RAL 7035
RAL 7035
RAL 8017
RAL 8017
RAL 9002
RAL 9002
RAL 9006<br><span style="font-size: 7pt;">SILVER</span>
RAL 9006
SILVER
RAL 9007<br><span style="font-size: 7pt;">SILVER METALLIC</span>
RAL 9007
SILVER METALLIC
RAL 9010
RAL 9010
Pruszyński Company guarantess realization of each order in one colour shade. Although due to technological process of covering paint to steel shets there is possibility for occuring difference in colour shade in different deliveries.

Regarding this please inform sales person if different delivery is continuation of previous orders.

Product description

Welna Sciana plus

A wall plate with a core of mineral wool (PWS2-MW) is another, much more advanced generation of this product. Along with the introduction of a new generation, we have also expanded the product range available to customers, with a hidden lockboard (PWS2-MW-PL). What is very important, the new variant has been designed specifically for synergy with our other products, including a core with polyurethane foam core (PWS-PIR-ST, PWS-PIR-PL).

The use of dedicated hidden lock solutions as well as parameters allows you to easily combine both products on investments, giving greater flexibility in design and also achieving the desired physical parameters in specific segments of the building.