Karta produktu
PWD – PIR – 80 – ROOF Sandwich panel – Polyurethane foam – visible fastening
|
||||||||||||||
PWD -PIR -80 - ROOF Sandwich panel - Polyurethane foam - visible fasteningTechnical specificationGeneral informationcore
polyurethane PIR
thickness of panel
80 mm
effective width
1050 mm
total width
1069 mm
weight of 1m2
11,49 kg
weight of 1mb
12,07 kg
min length of panel
2,0 mb
max length of panel
see Length of panel
thickness of steel sheet
0,5 mm
type of external profile
High trapezoidal
type of internal profile
trapezoidal - Tmicro - M coverings
polyester glossy/mat, polyurethane, HPS200, aluzinc
Physical properties Material properties Lambda λD coefficient
0,022 W/mK
Współczynnik przeCoefficient of heat transfer UD,S
0,28 W/m2K
Core density
40 ±3 kg/m³
Weight
11,00 kg/m2
Mechanical resistance Compressive strength
0,095 MPa
Ultimate tensile strength
0,070 MPa
Reduced shear strength at long -term load
0,04 MPa
Shear strength
0,075 MPa
Shear modulus
2,90 MPa
Flexural strength in span Positive bending moment
5,63 kNm/m
Positive bending in higher temperature
5,02 kNm/m
Negative bending moment
4,58 kNm/m
Negative bending in higher temperature
4,07 kNm/m
Resistance to bending over the inner support Positive bending moment
3,74 kNm/m
Positive bending in higher temperature
3,32 kNm/m
Negative bending moment
4,19 kNm/m
Negative bending in higher temperature
4,19 kNm/m
Creasing strength (external surface) in the span
256 MPa
In the span, higher temperature
228 MPa
Over the central support
280 MPa
Over the central support, higher temperature
280 MPa
Creasing strength (internal surface) In the span
144 MPa
Over the central support
108 MPa
Other properties Reaction to fire (all usage)
B-s2,d0
Fire resistance
NPD
External exposure to fire
Broof
Water permeability
Class A 1200 Pa
Air permeability
+(C=0,0201, n=0,7506); -(C=0,3664, n=0,5099)
Resistance to point load
No deformation or damage of core and facings
Water vapour permeability
impermeable
Insulation of sound propagating in the air
23(-1;-3) dB
Sound absorption
0,20
Creep coefficient t = 2000h
1,67
Creep coefficient t = 100000h
2,53
Durability
All colours
Length of panelsPermissible panel lengths depending on the color of the cladding (minimum length - 2.5 MB). group I (very bright colors)Maximum length 18 m
RAL 9001*
RAL 1015
RAL 7035
RAL 9002
RAL 9010
group II (bright colors)Maximum length 15 m
RAL 9022*
RAL 7040*
RAL 7037*
RAL 6033*
RAL 6021*
RAL 6018*
RAL 5024*
RAL 5018*
RAL 5012*
RAL 2009*
RAL 2008*
RAL 2004*
RAL 2003*
RAL 2000*
RAL 1035*
RAL 1023*
RAL 1019*
RAL 1017*
RAL 1014*
RAL 1004*
RAL 1003*
RAL 1002
RAL 1021
RAL 7000
RAL 9006
group III (dark colors)Maximum length 12 m
RAL 7022*
RAL 7015*
RAL 6020*
RAL 6011*
RAL 6003*
RAL 6000*
RAL 5022*
RAL 50011*
RAL 5009*
RAL 5005*
RAL 5002*
RAL 3013*
RAL 3003*
RAL 3002*
RAL 3000*
PM RR 033
PM RR 750
PM RR 011
RAL 8016
PUM RR 028
PMG RR 033
PMG RR 028
PMG RR 750
PMG RR 011
PM Dark Walnut
Golden Oak
RAL 3011
RAL 3005
RAL 8023
RAL 6005
RAL 6029
RAL 5010
RAL 9005
RAL 8017
RAL 7016
RAL 7024
RAL 9007
ATTENTION! Considering that dark colors from group III are subject to much larger thermal loads than boards in very light and light colors from group I and II should be assessed depending on the loads, what plates system on the wall is possible to be used. * The colors marked with the star are not available in the standard offer. Please direct individual queries in terms of colors using the contact form. Read more below. Recommendations for the selection of plates in the context of thermal loadsDuring projecting it’s important to include difference in temperature of external and internal cladding of sandwich panels.Gradients of temperatues due to difference in external temperature T1 and internal temperature T2 are dependent on few factors: Purpose of building (range of temperatures inside building T2) localization of building – position due to sun colour of external steel cladding (T1). Depending on latitude, height above sea level and distance from sea on europe continent are use 4 different levels of winter temperature (T1 – external cladding): 0, -10oC, 0, -20oC, (for ex. Poland) 0, -30oC, (for ex. scandinavian countries) Temperatures of external cladding of roof panel which is covered with snow layer is 0oC. For calculation was assumed external temperature in winter of -20 oC. Temperature of external cladding T1 has maximum value during summer and is depending of colour and grade of reflection of surface. Values T1, which are minmal for calculation bearing status (SGN) and are proper for calculations of limit status of use (SGU) are:
where RG – grade of reflextion in ratio of magnesium oxide = 100% Transport recommendationsRecommended ways of transport for sandwich panels:
StorageSandwich panels should be storage maximum 2 packages one on another. In below chart you can see what is maximal quantity of panels in one package.
All packages should be storage on flat surface with possibility to discharging water. ATTENTION !!!
MaintenanceIn order to extend durability of roofs and elevations it’s recommended to check and conservative it.
ATTENTION!
Pruszyński Sp. z o.o. is not in charge of possible accidents during carrying out all following actions. Polyester glossy
Technical specification of the coatingthickness of coating
25 µm
corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
possibility of bending
Good ★★☆☆
Available colours
RAL 9010
Golden Oak
RAL 9002
RR 032
RAL 3011
RR 028
RAL 3005
RAL 1002
RAL 8023
RAL 1015
RAL 3016
RAL 1021
RAL 6005
RAL 8004
RAL 5010
RAL 7000
RAL 6029
RAL 8017
RAL 9005
RAL 7016
RAL 7024
RAL 7035
RAL 9007
RAL 9006
Polyester mat PM 35um
Technical specification of the coatingthickness of coating
35 µm
corrosion resistance
Wysoka ★★★☆
UV resistance
Dobra ★★☆☆
possibility of bending
Dobra ★★☆☆
Available colours
PM Dark Walnut
PMG RAL 7016
PMG RR 033
PMG RAL 8017
PMG RR 032
PMG RR 028
PMG RR 750
PMG RR 011
PURLAK
Technical specification of the coatingthickness of coating
50 µm
corrosion resistance
Wysoka ★★★★
UV resistance
Wysoka ★★★☆
possibility of bending
Wysoka ★★★☆
Available colours
PU RAL 7016
PU RAL 9005
PU RAL 8017
PU RR 028
PU RAL 8004
PURMAT
Technical specification of the coatingthickness of coating
50 µm
corrosion resistance
Wysoka ★★★★
UV resistance
Wysoka ★★★★
possibility of bending
Wysoka ★★★☆
Available colours
PUM RAL 7016
PUM RR 033
PUM RAL 8017
PUM RR 028
PUM RR 011
PUM RR 750
AZ - aluzinc
Technical specification of the coatingAvailable colours
AZ – aluzynk
Product descriptionPanel with visible fasteningPIRTECH ROOK (visible mounting) boards with a maximum modular width of 1050 mm allow for simple and quick installation to various types of structures with the help of Kalotka and appropriate through fasteners. The uniquely designed longitudinal contacts (locks) of the pen and wpust ensure very good tightness, fire resistance and quick assembly. The shape of the outer surface (trapezoidal profile) allows you to carry high loads as well as can be used in single -span and multi -span systems When connecting roof slabs in length, it is necessary to cut the upper plate, i.e. the plate from the ridge side.
The undercut length can be: D = 50, 100, 150, 200, 250 and max 300 mm. Note: The total length of the plate contains the selected undercut length regardless of its size. For example, a 6000 mm long plate with a undercut of 200 mm = 6000 mm (5800 mm core + 200 mm sheet). Blachy Pruszyński performs two types of undercuts: – full undercut, i.e. an internal sheet cut, tape on the outer trapezoidal cladding, undercutting of foam along the entire thickness of the plate core, – incomplete undercut, i.e. cutting the inner sheet, undercutting of foam along the entire thickness of the core of the plate. Individual undercut widths (regarding the range only from 50 to 300 mm) are possible, but without a tape on the outer – trapezoidal cladding with undercut of foam along the entire thickness of the core of the plates. For PWD-PIR 40, 60, 80, 100, 120 min. The length of the plates with full undercut is 5,000 mm. Plates in lengths below 5,000 mm can only be made without a tape on the outer – trapezoidal cladding. For PWD-PIR panels 160 min. The minimum length of the panels with full undercut is 4,000 mm. The PWD -PIR 160 board in a length of below 4,000 mm can only be made without a tape on the outer – trapezoidal cladding. Tags |
||||||||||||||