Karta produktu
PWD-PIR-60 – Roof sandwich panel – polyurethane foam – visible fastening
|
||||||||||||||
PWD-PIR-60 - Roof sandwich panel - polyurethane foam - visible fasteningTechnical specificationTechnical InformationThe polyurethane foam-core roof sandwich panel, manufactured by the Blachy Pruszyński Company, is produced on a state-of-the-art production line in accordance with the highest quality standards. It offers high thermal insulation performance combined with low surface weight. The PIR foam core is sandwiched between two layers of galvanized, coated sheet cladding. Our product line offers a variety of colours and coatings to choose from. The roof profile of the outer cladding (trapezoidal, 40 mm high) ensures excellent water drainage performance.
core
PIR polyurethane
panel thickness
60 mm
effective width
1,050 mm
overall width
1,147 mm
min. roof pitch *
5% (3rd)
min. roof pitch **
7% (4th)
weightper 1 m²
10.69 kg
size: 1 MB
11.23 kg
min. panel length
2.0 mb
Maximum panel length
see - panel lengths
sheet metal thickness
0.5 mm
external profiling
trapezoidal - T40mm
internal profiling
trapezoid - T, micro - M coatings
glossy/matte polyester, polyurethane, HPS200
Physical PropertiesMaterial Properties Thermal conductivity coefficient λD
0.022 W/mK
Heat transfer coefficientUD,S [W/m²K]
0,36
Heat Transfer CoefficientUC [W/m²K]
0,37
Core density
40 ±3 kg/m³
Other Properties Fire Reaction (All Applications)
B-s1,d0
Fire resistance
NPD
The roof's resistance to external fire
Broof
Water permeability
Class A 1200 Pa
Air permeability
+(C=0.0201, n=0.7506); -(C=0.3664, n=0.5099)
Resistance to concentrated loads
No damage to the core or cladding
Water vapor permeability
Waterproof
Sound insulation against airborne noise
23(-1;-3) dB
Sound Absorption
0,20
Creep coefficient t = 200h
1,67
Creep factor t = 100,000 h
2,53
Shelf Life
All colors
Panel lengthsPermissible panel lengths vary depending on the cladding color (minimum length: 2.5 running meters). The assembly of panels exceeding the recommended lengths is the responsibility of the customer. Group I (very light colors)Maximum length 18 m
RAL 9002
RAL 9010
RAL 9001*
Group II (light colors)Maximum length 15 m
RAL 1002
RAL 1015
RAL 1021
RAL 7000
RAL 7035
RAL 9006
SILVER
RAL 1003*
RAL 1014*
RAL 1004*
RAL 1017*
RAL 1019*
RAL 1023*
RAL 1035*
RAL 2000*
RAL 2003*
RAL 2008*
RAL 2004*
RAL 2009*
RAL 5012*
RAL 5018*
RAL 5024*
RAL 6018*
RAL 6021*
RAL 6033*
RAL 7037*
RAL 7040*
RAL 9022*
Group III (dark colors)Maximum length 12 m
RAL 3005
RAL 3011
RAL 5010
RAL 6005
RAL 6029
RAL 7016
RAL 7024
RAL 8017
RAL 8023
COPPER
RAL 9005
RAL 9007
SILVER METALLIC
PMG R750
PMG R011
PMG R028
PMG R033
Light Walnut
Royal Oak
PUM R028
RAL 3000*
RAL 3002*
RAL 3003*
RAL 3013*
RAL 5002*
RAL 5005*
RAL 5009*
RAL 5011*
RAL 5022*
RAL 6000*
RAL 6003*
RAL 6011*
RAL 6020*
RAL 7015*
RAL 7022*
RAL 8016*
ATTENTION! Given that dark-colored panels from Group III are subject to significantly higher thermal loads than very light- and light-colored panels from Groups I and II, it is necessary to assess during the design phase, depending on the loads, which panel layout on the roof is feasible. * Colors marked with an asterisk are not available in the standard product range. Please submit individual inquiries regarding colors directly via the contact form. Read more below. Recommendations for Selecting Plates in the Context of Thermal LoadsWhen designing, temperature differences between the claddings of sandwich panels must be taken into account. The temperature gradients resulting from the difference between the outdoor temperatureT1 and the indoor temperatureT2 depend on several factors:
Depending on latitude, elevation above sea level, and distance from the sea, four different winter temperature levels are used on the European continent (T1—exterior cladding):
The temperature of the outer cladding for roof panels covered with a layer of snow is0°C. An outdoor temperature of -20 °Cduring the winter was used for the calculations. The temperature of the exterior cladding,T1, reaches its maximum value in the summer and depends on the color and reflectivity of the surface. TheT1 values, which are the minimum values for strength-of-resistance (SGN) calculations and are appropriate for serviceability limit state (SGU) calculations, are adopted as follows:
whereRG is the reflectance of the rays relative to magnesium oxide = 100% The table below shows a classification by color group for the individual colors available in the Pruszyński Company product line. Shipping RecommendationsRecommended modes of transportation for sandwich panels:
Storage RecommendationsSandwich panels should be stored in stacks; a maximum of two stacks may be placed on top of each other. The table below lists the maximum number of panels that can be packed together in a single package.
ATTENTION!!! For wall panels with visible fastening (applies to PIR panels), the top side of the panels in the package is the facade side—please pay special attention to this! Maintenance and CleaningTo extend the service life of roofs and facades made of coated sheet metal, they should be inspected and maintained regularly.
Pruszyński Company Sp. z o.o. is not liable for any accidents that may occur as a result of performing the above activities. RecommendationsTransport and Storage
Maintenance and Cleaning
PURMATpolyurethane coating, matte
Technical specification of the coatingcoating thickness
50 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★★
machinability
High ★★★☆
Technical Warranty
up to 30/50 years
Available colours PUM R011
PUM R028
PUM R033
PUM R750
PUM RAL 7016
PUM RAL 8017
PURLAKpolyurethane coating, gloss
Technical specification of the coatingcoating thickness
50 µm
corrosion resistance
High ★★★★
UV resistance
High ★★★☆
machinability
High ★★★☆
Available colours PU RAL 7016
PU RAL 9005
PMG35®coarse-grained matte polyester
Technical specification of the coatingcoating thickness
35 µm
corrosion resistance
High ★★★☆
UV resistance
Good ★★☆☆
machinability
Good ★★☆☆
Available colours0.50 mm PMG R011
PMG R028
PMG R032
PMG R033
PMG R750
PMG RAL 7016
PMG RAL 8017
PS25glossy polyester
Technical specification of the coatingCoating thickness
25 µm
Corrosion Resistance
High ★★★☆
UV resistance
Good ★★☆☆
Machinability
Good ★★☆☆
Available coloursColor palette R028
R032
RAL 1002
RAL 1015
RAL 1021
RAL 3000
RAL 3005
RAL 3011
RAL 3016
RAL 5010
RAL 6005
RAL 6029
RAL 7000
RAL 7035
RAL 9002
RAL 7016
RAL 7024
RAL 8004
RAL 8017
RAL 8023
COPPER RAL 9005
RAL 9006
SILVER RAL 9007
SILVER METALLIC RAL 9010
0.50 mm R028
R032
RAL 1002
RAL 1015
RAL 1021
RAL 3000
RAL 3005
RAL 3016
RAL 5010
RAL 6005
RAL 6029
RAL 7000
RAL 7035
RAL 9002
RAL 7016
RAL 7024
RAL 8004
RAL 8017
RAL 8023
COPPER RAL 9005
RAL 9006
SILVER RAL 9007
SILVER METALLIC RAL 9010
0.70 mm RAL 1002
RAL 3011
RAL 3016
RAL 5010
RAL 6029
RAL 7035
RAL 9002
RAL 7016
RAL 8017
RAL 9006
SILVER RAL 9007
SILVER METALLIC RAL 9010
Product Description Panel with visible fasteningPIRTECH roof panels ( with visible fastening), with a maximum modular width of 1,050 mm, allow for quick and easy assembly on various types of structures using clips and appropriate through-fasteners. Uniquely designed tongue-and-groove longitudinal joints (locks) ensure excellent airtightness, fire resistance, and quick assembly. The shape of the outer surface (trapezoidal profile) allows it to withstand high loads and makes it suitable for use in single-span and multi-span systems.
When joining roof panels end-to-end, it is necessary to cut into the top panel—that is, the panel on the Ridge side.
The cutout length can be: D = 50, 100, 150, 200, 250, and a maximum of 300 mm.
Blachy Pruszyński Company performs two types of undercuts: – full cut, i.e., an incision in the inner sheet metal, tape on the outer trapezoidal cladding, and a cut through the entire thickness of the panel core foam, – Incomplete cut, i.e., an incision in the inner sheet metal and a cut through the entire thickness of the panel core foam. Custom cut-out widths (applicable only to the range from 50 to 300 mm) are possible, but without tape on the outer trapezoidal cladding, with the foam cut out across the entire thickness of the panel core. For PWD-PIR 40, 60, 80, 100, and 120 min. panels, the length of panels with a full cutout is 5,000 mm. Panels shorter than 5,000 mm may only be manufactured without tape on the outer trapezoidal cladding. For PWD-PIR 160 panels, the minimum length of panels with a full cutout is 4,000 mm. PWD-PIR 160 panels shorter than 4,000 mm may only be manufactured without tape on the outer trapezoidal cladding. TagsExplore our selection of accessories
Fasteners for sandwich panels (self-tapping screw for up to 12 mm)
Fasteners for sandwich panels
See product
Fasteners for sandwich panels (self-tapping screw for up to 6 mm)