Technical specification

General information

Installation : roof panels for seams should be mounted at positive temperatures. Pruszyński sheets allow a different assembly method, consistent with roofing art.


Effective width
510 mm

Seam high
25 mm

Material
S 250 GD + Z 200 or 275
Max. recommended length of sheet
9 mb
Min. length of sheet
0,5 mb
Thickness
0,50 / 0,70 mm
Covering
polyester glossy, polyester matt, PURLAK, PURMAT
Accessories
Screws, nails, sealing tapes, flashings
Appliance
covering of roofs with minimal slope 8o (14%)
Panel PD510 Nano przekroj

Recommendations

Panels storage

Packages should be stored in dry and well-ventilated spaces, without humidity condensation  between the sheets. Collective packages should be put on blocks about 20cm height upon the surface. If panels are stored more than 3 weeks from the production date – panels should be checked and separators should be put between to allow for free air circulation. All information about the way and period of storage are on the protective foil, product labels and our catalogues, assembly instructions and website.

Protective foil

Protective foil is used to safe the roof panels against mechanical damages. It should be removed directly at the assembly stage and it should protect panels against humidity and sun during the storage period. Non compliance with above rules may cause difficulties when removing the foil from sheets and dirty after the glue.

Maintance

Generally, roofs with standing seam panels do not demand any special maintenance. Nevertheless, so as to prevent the risk of to fast damaging of the building and regardless the localization, wall covering and roof covering must be checked and maintenanced once a year, at least. Deposit, industrial dust (from lime plants, cement limes, foundries and mines) which cause damage of varnish cover as a result of chemical reaction with water and leafs, which cause fading of organic cover due to rotting should be removed from panel surface. Any lack  in covering should be cleaned and painted with special touch-up paints.

Final warnings

1. Special electric vibrating scissors or irregular, nibblers and hand scissors should be used to cut sheet.  Tools which cause damage of varnish and galvanized covering due to the produced heat when cutting the steel are forbidden, for instance angle grinder.

2. You can walk on the roof with shoes with soft bottom, make steps in the bottom of waves, on patches. Before you start walking on the roof, all the screws must be assembled.

3. Small damages of covering from assembly could be painted with touch-up paints. The surface must be cleaned from dirt and oil.

4. Steel chips from the cutting or drilling must be removed with soft brush – its rusting may damage the steel surface.

5. Dirt, which stays after assembler work or dirt from daily exploitation should be removed with normal cleaning agents.

6. Use of any steel treatments (including chimney cap, rainwater cleaner, etc.) from copper sheets on roofs and elevations from galvanized and covered sheets is forbidden.

Choose a coating:
More information about the coatings
polyester glossy

Technical specification of the coating

thickness of layer
25 µm
corossion resistance
High ★★★☆
UV resistant
Good ★★☆☆
possibility of bending
Good ★★☆☆
Aesthetic warranty
10 years
technical warranty
30 years

Available colours

polyester matt structular

Technical specification of the coating

thickness of layer
35 µm
corossion resistance
High ★★★☆
UV resistant
Good ★★☆☆
possibility of bending
Good ★★☆☆
Aesthetic warranty
15 years
technical warranty
35 years

Available colours

PURMAX 40 um

Technical specification of the coating

thickness of layer
40 µm
corossion resistance
High ★★★★
UV resistant
High ★★★☆
possibility of bending
High ★★★☆
Aesthetic warranty
20 years
technical warranty
40 years

Available colours

PURLAK 50 um

Technical specification of the coating

thickness of layer
50 µm
corossion resistance
High ★★★★
UV resistant
High ★★★☆
possibility of bending
High ★★★☆
Aesthetic warranty
do 30 years
technical warranty
50 years

Available colours

PURMAT 50 um

Technical specification of the coating

thickness of layer
50 µm
corossion resistance
High ★★★★
UV resistant
High ★★★★
possibility of bending
High ★★★☆
Aesthetic warranty
up to 30 years
technical warranty
50 years

Available colours

Firma PRUSZYŃSKI gwarantuje każdorazowo realizację poszczególnego zamówienia w jednakowym kolorze (odcieniu). Z uwagi na skomplikowanie procesów powlekania możliwe jest jednak występowanie różnic w odcieniach pomiędzy poszczególnymi dostawami.

Odpowiedzialność za kolor w związku z tym ograniczona jest jedynie do jednej dostawy.

W związku z powyższym w przypadku domawiania blach do konkretnej partii bardzo prosimy o zaznaczenie na zamówieniu lub poinformowanie Handlowca, iż jest to kontynuacja zlecenia oraz dostarczenia próbki kolorystycznej.

Celem zapewnienia spójności kolorystycznej płyty warstwowych z innymi elementami takimi jak np. obróbki blacharskie należy zamawiać je u jednego dostawcy.

Pruszyński Company guarantess realization of each order in one colour shade. Although due to technological process of covering paint to steel shets there is possibility for occuring difference in colour shade in different deliveries.

Regarding this please inform sales person if different delivery is continuation of previous orders.

Product description

blacha na rąbek nano

Roof panels with standing seam

The edge finish option with cut edges enabling assembly on the start strip.

The edges are cut on two sides of the panel. This allows you to twist the panel depending on the direction in which the assembly is carried out.

The PD510 Nano panel only occurs in an option with cut edges.

See our offer of accessories

Choose the best accessories for your roof!

Wkręty samowiercące typu TORX TORX self-drilling screws (staples)
Fasteners for trapezoidal sheets, roof tiles, karo panels (short)
See product
Listwa podkalenicowa Ridge strip
Sheet metal processes
See product